| 注册
首页|期刊导航|烟草科技|以烟草和高聚物为标样的烟草近红外光谱定量模型传递效果评价

以烟草和高聚物为标样的烟草近红外光谱定量模型传递效果评价

王萝萍 马翔 陆俊平 韩莹 刘欣 祁飞燕 马洪锋 杨舒涵 郑博文

烟草科技2025,Vol.58Issue(7):10-19,10.
烟草科技2025,Vol.58Issue(7):10-19,10.DOI:10.16135/j.issn1002-0861.2025.0041

以烟草和高聚物为标样的烟草近红外光谱定量模型传递效果评价

Evaluation of transfer effects of near-infrared spectral quantitative models for tobacco using tobacco and polymer as standard samples

王萝萍 1马翔 1陆俊平 1韩莹 1刘欣 1祁飞燕 1马洪锋 2杨舒涵 3郑博文3

作者信息

  • 1. 云南中烟工业有限责任公司原料中心,昆明市五华区龙泉路548号 650231
  • 2. 红塔烟草(集团)有限责任公司玉溪卷烟厂,云南省玉溪市红塔大道118号 653100
  • 3. 红云红河烟草(集团)有限责任公司昆明卷烟厂,昆明市五华区红锦路366号 650000
  • 折叠

摘要

Abstract

To evaluate the transfer effects of near-infrared(NIR)spectral quantitative models for the main conventional chemical indexes of tobacco using polymers as standard samples,and to promote the application of NIR spectroscopy in the tobacco industry,spectral transfer models were established for the same brand and different brands of NIR spectrometers from slave to the same host instruments using piecewise direct standardization(PDS)and spectral space transformation(SST),with tobacco and 17 polymers as the standard materials.Principal component analysis and Mahalanobis distances between the transferred and original spectra from the host instrument were used to optimize the PDS and SST parameters.The effectiveness of the transfer models was evaluated using the root mean square error of prediction(RMSEP)between the predicted values based on the transferred spectra from the slave instrument and the determined values obtained using reference methods.The results showed that:1)The optimal PDS parameters were a segment wavelength window width of 6 cm-1 and six PLS principal factors.2)The optimal SST parameter was six PLS principal factors.3)The RMSEP values for total nitrogen,nicotine,and total sugar in the 90 external test samples across the same brand and different brand NIR spectrometer model transfers indicated that the calibration performance of the spectral transfer models was as follows,ranked from best to worst:tobacco standard sample+SST,tobacco standard sample+PDS,polymer standard sample+PDS,and polymer standard sample+SST.Tobacco performed better than the polymers as standard samples for transferring NIR models of total nitrogen,nicotine,and total sugar in flue-cured tobacco leaves.These findings provide a foundation for the wider application of NIR spectroscopy in the tobacco industry.

关键词

烟草/近红外光谱/模型传递/标样/高聚物/常规化学指标

Key words

Tobacco/Near-infrared spectroscopy/Model transfer/Standard sample/Polymer/Conventional chemical index

分类

轻工纺织

引用本文复制引用

王萝萍,马翔,陆俊平,韩莹,刘欣,祁飞燕,马洪锋,杨舒涵,郑博文..以烟草和高聚物为标样的烟草近红外光谱定量模型传递效果评价[J].烟草科技,2025,58(7):10-19,10.

基金项目

云南中烟工业有限责任公司重点项目"云南中烟烟叶近红外模型统一构建与应用研究"(2023YL05). (2023YL05)

烟草科技

OA北大核心

1002-0861

访问量0
|
下载量0
段落导航相关论文