| 注册
首页|期刊导航|中国空间科学技术(中英文)|航天器用机械泵驱动两相流体回路在轨测试性能分析

航天器用机械泵驱动两相流体回路在轨测试性能分析

孟庆亮 韦广朗 于峰 杨涛 赵振明 朱许

中国空间科学技术(中英文)2025,Vol.45Issue(4):70-78,9.
中国空间科学技术(中英文)2025,Vol.45Issue(4):70-78,9.DOI:10.16708/j.cnki.1000-758X.2025.0059

航天器用机械泵驱动两相流体回路在轨测试性能分析

Performance analysis of on-orbit testing of mechanically pumped two-phase loop for spacecraft

孟庆亮 1韦广朗 1于峰 1杨涛 1赵振明 1朱许1

作者信息

  • 1. 北京空间机电研究所,北京 100094||先进光学遥感技术北京市重点实验室,北京 100094
  • 折叠

摘要

Abstract

Mechanistically pumped two-phase loop(MPTL)is a two-phase heat transfer device,which possesses the strong heat transfer ability through the release of latent heat of liquid and vapor phase change during flow boiling process.MPTL shows a promising prospect in thermal control of spacecraft.The objective of the present study is to focus on the working characteristics and stability of MPTL under the microgravtiy environment on orbit.One MPTL,which included one shield centrifugal pump,one two-phase temperature controlling accumulator and one micro channel evaporator,was designed and constructed to investigate the characteristics of start-up,phase-changing heat transfer,and temperature-controlling for MPTL aboard one satellite.Test results shows that MPTL shows good working performance and stable operating behavior in microgravity environment.The two-phase accumulator presents good heat transfer performance under microgravity condition.Its temperature control accuracy reaches to±0.1 K.The passive cooling function of accumulator is validated,and its cooling rate reaches to 1℃/min.The temperature difference between the measuring points of vapor and liquid phase for the accumulator are in the range of 0.3~1.0 K when the pump is working.The temperature control accuracy of the evaporator is in the range of±0.1~±0.3 K at the two rotation speeds.Superheating phenomenon takes place during the phase changing process of the loop and it leads to a higher 7~8 K temperature at the evaporator's outlet than the temperature control point.By comparing the results under the two rotation speeds,the superheat time and superheat temperature are related with the rotation speeds.The two-phase temperature controlling accumulator using the capillary structures can assure the function of high-precision temperature control and high-efficiency two-phase fluid management and control for MPTL under the microgravity condition.The phase transition characteristic for vapor-liquid is related to the mass flowrate of the loop.The stability of temperature on the evaporator is related to the fluid quality of its interior fluid.The study would contribute to the engineering design basis for the technology of two-phase flow and heat transfer,and would promote the development of active two-phase thermal control technology for space.

关键词

航天器热控/机械泵驱动两相流体回路(MPTL)/在轨测试/对流换热/微重力

Key words

spacecraft thermal control/mechanically pumped two-phase loop(MPTL)/on-orbit testing/convection heat transfer/microgravity

分类

航空航天

引用本文复制引用

孟庆亮,韦广朗,于峰,杨涛,赵振明,朱许..航天器用机械泵驱动两相流体回路在轨测试性能分析[J].中国空间科学技术(中英文),2025,45(4):70-78,9.

基金项目

国家自然科学基金(51806010) (51806010)

中国空间科学技术(中英文)

OA北大核心

1000-758X

访问量0
|
下载量0
段落导航相关论文