摘要

Abstract

Proper orthogonal decomposition(POD)method has been applied to establish reduced-order models of transformer temperature fields due to its computational efficiency and accuracy in calculating physical fields.The existing POD reduced-order model is incapable of simulating the transient temperature fields of transformers under different operating conditions.Therefore,this paper proposes a reduced-order modelling method adaptable to various transformer operating conditions by developing a reduced-order model for transformer temperature fields calculation based on double proper orthogonal decomposition(DPOD).Firstly,a reduced-order model for dry transformers based on POD is established under rated conditions.Secondly,the accuracy of this reduced-order model is calculated at varying loads and inlet wind speeds.Finally,the reduced-order models for dry-type transformers based on DPOD are established under conditions of load variations and inlet wind speed variations respectively to verify the accuracy of the reduced-order models under these conditions and compare them with the POD-based reduced-order models.The results indicate that the newly established model can maintain the accuracy of temperature field calculations when the operating conditions of the transformers change.

关键词

干式变压器/温度场/降阶方法/双重本征正交分解

Key words

dry-type transformer/temperature field/reduced-order method/double proper orthogonal decomposition(DPOD)

分类

信息技术与安全科学

引用本文复制引用

张泽懿,蓝海娟,唐文虎..基于双重本征正交分解的干式变压器温度场降阶建模方法[J].广东电力,2025,38(6):56-67,12.

基金项目

广东省重点研发计划项目(2023B0909040003) (2023B0909040003)

广东电力

OA北大核心

1007-290X

访问量0
|
下载量0
段落导航相关论文