| 注册
首页|期刊导航|生物骨科材料与临床研究|SolidWorks软件在胫骨高位截骨术前计划中应用的可靠性分析

SolidWorks软件在胫骨高位截骨术前计划中应用的可靠性分析

李丹 乔锋 张保刚 孙鹏

生物骨科材料与临床研究2025,Vol.22Issue(4):13-17,27,6.
生物骨科材料与临床研究2025,Vol.22Issue(4):13-17,27,6.DOI:10.3969/j.issn.1672-5972.2025.04.003

SolidWorks软件在胫骨高位截骨术前计划中应用的可靠性分析

Reliability analysis of the application of SolidWorks software in preoperative planning of high tibial osteotomy

李丹 1乔锋 2张保刚 2孙鹏1

作者信息

  • 1. 陕西中医药大学,陕西 咸阳,712000||西安交通大学附属红会医院中西医结合骨科,陕西 西安,710054
  • 2. 西安交通大学附属红会医院中西医结合骨科,陕西 西安,710054
  • 折叠

摘要

Abstract

Objective To evaluate the accuracy and reliability of using SolidWorks software for preoperative planning of high tibial osteotomy(HTO).Methods Data from 42 patients(81 knees)with medial intertrochanteric arthritis of the knee who underwent open wedge HTO preoperative planning using SolidWorks between June 2019 and March 2021 were retrospectively analyzed at Honghui Hospital,Xi'an Jiaotong University.Full-length radiographs of both lower extremities in the weight-bearing position were taken preoperatively and 6 weeks postoperatively and measured.The weight-bearing line ratio(WBLR),corrected angle,medial proximal tibial angle(MPTA)and mechanical femur-tibia angle(mFTA)preoperatively and at 6 weeks postoperatively were compared.Clinical outcomes were evaluated using the knee society score(KSS).Results All 42 patients were followed up for 4 to 32 months,with a mean of(25.6±6.8)months.At 6 weeks postoperatively,the WBLR was corrected from 17.2%±12.1%preoperatively to 50.7%±5.7%postoperatively(P<0.05).Comparison between the preoperative predicted corrected angle of 8.1°±3.5° and the corrected angle of 9.2°±3.0° measured at 6 weeks postoperatively,the difference was statistically significant(P<0.05).The MPTA was corrected from 83.2°±2.6° preoperatively to 89.0°±2.0° postoperatively(P<0.05),the mFTA was corrected from 5.5°±2.9° entropion preoperatively to 1.6°±1.5°ectropion postoperatively(P<0.05).The Knee Society's knee score improved from(75.7±8.1)scores preoperatively to(94.9±3.9)scores postoperatively(P<0.05),and the knee social function score improved from(81.1±8.3)scores preoperatively to(96.5±4.7)scores postoperatively(P<0.05).Conclusion SolidWorks software provides high accuracy and reliability in preoperative planning of open wedge HTO in patients with medial compartment arthritis of the knee.

关键词

开放楔形胫骨高位截骨术/SolidWorks/术前规划/矫正角度/负重线比

Key words

Open wedge high tibial osteotomy/SolidWorks/Preoperative planning/Corrected angle/Weight-bearing line ratio

分类

医药卫生

引用本文复制引用

李丹,乔锋,张保刚,孙鹏..SolidWorks软件在胫骨高位截骨术前计划中应用的可靠性分析[J].生物骨科材料与临床研究,2025,22(4):13-17,27,6.