中国医疗设备2025,Vol.40Issue(8):32-37,6.DOI:10.3969/j.issn.1674-1633.20240628
智能红外测温仪的测量影响因素研究
Research on the Influencing Factors of Intelligent Infrared Thermometer Measurement
摘要
Abstract
Objective By analyzing the working principle of the intelligent infrared thermometer and conducting temperature measurement experiments on the human body for verification,to study the influence of various factors such as the distance and angle between the measurement target and the intelligent infrared thermometer,as well as environmental temperature and humidity,on the results of the intelligent infrared thermometer.Methods Based on the principle of infrared temperature measurement,a walk-in environmental test chamber was used to simulate the temperature measurement conditions of the intelligent infrared thermometer under different temperatures and humidity.The data were analyzed using SPSS 22.0 statistical software,fully considering the influence of multiple factors such as distance,angle,temperature and humidity on the intelligent infrared thermometer.Results When only height was considered,there was a statistically significant difference in the measurement results of volunteers with a height of 190 cm using a glass thermometer and an intelligent infrared thermometer(P<0.05).There was no statistically significant difference in the measurement results between the glass thermometer and the intelligent infrared thermometer of the volunteers with a height of 160 cm(P>0.05).The measurement results were less affected by angle changes.However,angle alterations could have an impact on the measurement data(resulting in lower measurement values),especially when the measurement distance increased.When only the environmental temperature and humidity were considered as single factors,there were statistically significant differences in the measurement data when comparing the ambient temperature between 25℃and 35℃,as well as between 25℃and 10℃,and between 35℃,30%RH and 35℃,80%RH(P<0.05).With the interference of multiple factors,the accuracy of the measurement data would decline(the measured value will be lower).When considering the simultaneous interference of multiple factors such as distance,height and humidity,the maximum relative error was 2.7%and the maximum error was 1℃.Conclusion In practical application,the effective measurement distance of the intelligent infrared thermometer and the influence of environmental temperature and humidity on the temperature measurement results should be fully considered.When measuring temperature,the person being measured should be kept within the effective measurement distance.When the environmental temperature and humidity are too low or too high,measures should be taken to maintain the stability of temperature and humidity in the usage site and reduce the impact caused by adverse environmental factors.关键词
智能红外测温仪/测温仪/红外测温/测量角度/测量距离/影响因素Key words
intelligent infrared thermometer/thermometer/infrared temperature measurement/measuring angle/measuring distance/influencing factors分类
医药卫生引用本文复制引用
范书健,宋宁宁,裴晓娟,蒋硕,张在爱,田佳,张克..智能红外测温仪的测量影响因素研究[J].中国医疗设备,2025,40(8):32-37,6.基金项目
山东省医疗器械和药品包装检验研究院内部科研项目(NB202211). (NB202211)