摘要
Abstract
In recent years,with the rapid development of new energy construction,especially wind power and photovoltaics,and its power generation accounts for 16%of the total electricity consumption in the society.The energy structure is developing towards clean-liness and low carbon.While the construction of new energy stations is rapidly advancing,equipment problems are increasingly diverse and complex.By analyzing the process of tripping of the main transformer of a photovoltaic new energy station,discussing the causes of its failures and putting forward corresponding measures and suggestions,it provides some reference for the construction and operation and maintenance of similar stations.关键词
新能源/光伏电站/主变压器/断路器跳闸Key words
new energy/photovoltaic power station/main transformer/circuit breaker trip分类
信息技术与安全科学引用本文复制引用