航天器工程2025,Vol.34Issue(4):58-65,8.DOI:10.3969/j.issn.1673-8748.2025.04.008
基于故障定位的航天器BDR过流保护优化设计
Optimization Design of Spacecraft BDR Overcurrent Protection Based on Fault Location
井元良 1胡梦森 1李海津 1陈世杰1
作者信息
- 1. 北京空间飞行器总体设计部,北京 100094
- 折叠
摘要
Abstract
To address the need for distinguishing fault locations in the overcurrent protection of battery discharge regulator(BDR)within spacecraft power supply system,an overcurrent protec-tion optimization design based on fault location is proposed.In the event of a short circuit fault within the BDR,the protection switch is triggered immediately at a lower threshold,thereby minimizing the impact range of the fault.When a short circuit occurs in the bus,the protection switch operates at a high threshold to provide sufficient energy for fault clearance.The proposed optimization design has been validated through simulation and prototype experiments,demon-strating its capability to accurately locate the short circuit faults,adjust the protection threshold,and ensure the normal operation of the power system.关键词
航天器电源系统/蓄电池放电调节器/过流保护/故障定位Key words
spacecraft power supply system/BDR/overcurrent protection/fault location分类
航空航天引用本文复制引用