| 注册
首页|期刊导航|中国医学装备|双流注射技术中不同对比剂-生理盐水比例对冠状动脉CT血管造影图像质量的影响

双流注射技术中不同对比剂-生理盐水比例对冠状动脉CT血管造影图像质量的影响

原媛 卢昊 贺毅 李然 钟朝辉

中国医学装备2025,Vol.22Issue(8):29-35,7.
中国医学装备2025,Vol.22Issue(8):29-35,7.DOI:10.3969/j.issn.1672-8270.2025.08.006

双流注射技术中不同对比剂-生理盐水比例对冠状动脉CT血管造影图像质量的影响

Influence of different ratios of CA to saline on CCTA image quality in dual-flow injection technique

原媛 1卢昊 2贺毅 1李然 1钟朝辉1

作者信息

  • 1. 首都医科大学附属北京友谊医院放射科 北京 100050
  • 2. 首都医科大学燕京医学院医学影像学学系 北京 101300
  • 折叠

摘要

Abstract

Objective:To investigate the influence of different ratios of contrast agent(CA)to saline on image quality of coronary computed tomography angiography(CCTA)in dual-flow injection technique.Methods:A prospective study included 102 patients who were clinically diagnosed as suspected coronary heart disease(CHD)to undergo CCTA scan at Beijing Friendship Hospital,Capital Medical University,between March 2024 and October 2024.Ultimately,90 patients were enrolled,who adopted CA injection protocol of dual-flow injection technique.Patients were randomly divided into three groups using a random number table,with 30 patients in each group.The different ratios of CA to saline were adopted,which were respectively Group A(1:9),Group B(2:8),and Group C(3:7).For the reconstructed images,the computed tomography(CT)values of heart-related anatomical structures,which included superior vena cava,right atrium,right ventricle,left atrium,left ventricle,interventricular septum and each segment of the coronary artery,were measured respectively.At the same time,two radiologists,who possessed over 10 years of diagnostic experience of CCTA examination,conducted subjective evaluations for image quality.For the cases of disagreement,the consensus between them was reached through discussion.Results:In three groups,the total CA doses were respectively(42.75±5.22)ml,(47.08±5.83)ml and(50.64±6.29)ml,and the differences of that among the three groups was statistically significant(F=13.964,P<0.05).The differences of CT values of superior vena cava,right atrium,right ventricle,left atrium,left ventricle and aorta among three groups were significant(F=29.141,24.194,39.308,9.643,8.178,6.881,P<0.05).There were significant differences in the CT values of the proximal,mid,and distal segments of the left anterior descending(LAD),and the proximal and mid segments of the left circumflex(LCx)and right coronary artery(RCA)among three groups(F=7.114,9.106,3.851,6.075,4.025,7.349,5.756,P<0.05).However,there was not statistically significant difference was found among the three groups in the CT value of the distal segments of the LCx and RCA(P>0.05).There were significant differences in the subjective scores for the superior vena cava,right atrium and right ventricle among the three groups(H=8.939,29.105,32.180,P<0.05).The number of cases with 3-4 points at the superior vena cava,right atrium and right ventricle were respectively 25(83.3%),29(96.7%)and 30(100%)in group B,there was no case with 1 point.In addition,the imaging quality of right heart in group B was better than that in group A and C.There were no significant differences at left atrium,left ventricle,and each segment of coronary artery among three groups(P>0.05).Conclusion:For patients with clinically non-extreme body weight,the selection of the ratio(2:8)of CA to saline can effectively show relevantly anatomic structures of heart,and coronary artery vessels,including the right heart system,which belongs to the optimal solution.

关键词

双流注射技术/冠状动脉CT血管造影(CCTA)/图像质量/主观评价

Key words

Dual-flow injection technique/Coronary computed tomography angiography(CCTA)/Image quality/Subjective evaluation

分类

医药卫生

引用本文复制引用

原媛,卢昊,贺毅,李然,钟朝辉..双流注射技术中不同对比剂-生理盐水比例对冠状动脉CT血管造影图像质量的影响[J].中国医学装备,2025,22(8):29-35,7.

基金项目

国家自然科学基金(82272068) National Natural Science Foundation of China(82272068) (82272068)

中国医学装备

1672-8270

访问量4
|
下载量0
段落导航相关论文