郭晨雷 1戴建荣 1曹莹 1冯鑫 1张凯旋 1王振 1孙铭鉴 1宋勇利 1刘星 1刘文扬1
作者信息
- 1. 国家癌症中心 国家肿瘤临床医学研究中心 中国医学科学院北京协和医学院肿瘤医院放疗科 北京 100021
- 折叠
摘要
Abstract
Objective:To propose a novel radiotherapy marking method-the"#"-character method,which aimed at improving the accuracy and repeatability of positioning during radiotherapy.Methods:A specially"cross-shaped"stamp was designed by this study,which consisted of a handheld square base with a"cross-shaped"protrusion.Using this stamp,the extreme positions of end-expiration and end-inspiration were marked respectively at the laser-guided regions on the directly above and bilateral sides of the patient's body,and each position was printed a"+"character.Finally,a"#-shaped"signal was formed,which represented the full range of respiratory motion of patients.The study included two parts:surface displacement caused by respiration was simulated through a three-dimensional(3D)motion platform,which was used to conduct a phantom experiment for anthropomorphic dummy,A randomized controlled study involving 40 patients,who were treated between January and June 2024 at the Department of Radiotherapy,Cancer Hospital,Chinese Academy of Medical Sciences,were conducted.The cohort included 20 patients with breast tumor(Positioning the outer contour by exposing the chest)and 20 patients with thoracic tumor(fixed position of using thermoplastic film).These patients were divided into two groups for comparison,which received respectively the"#-shaped"method and the conventional"+-shaped"method.The cone-beam computed tomography(CBCT)images before treatment were used to compare the influences of the two kinds of marking methods on the positioning errors of patients with breast tumor and patients with thoracic tumor.Then,the statistical analysis was used to assess precision and accuracy of positioning.Results:The result of phantom experiment indicated that the positioning error of the"#-shaped"method was significantly better than that of the"+-shaped"method under various parameters of respiratory movement.Under three kinds of different respiratory cycles(3,4,and 5 seconds)and amplitudes(8,12,and 15 mm),the positioning errors of the"#-shaped"method were respectively(0.15±0.04)cm,(0.19±0.05)cm and(0.35±0.14)cm,while the"+-shaped"method were respectively(0.42±0.16)cm,(0.64±0.28)cm and(0.88±0.37)cm,and the differences were statistically significant(t=8.347,3.416,2.901,P<0.05).The results of actual patients indicated the positioning error[(0.97±0.32)cm]of the"#-shaped"method was significantly lower than[(1.62±0.47)cm]of the"+-shaped"method for patients with breast tumor(Positioning the outer contour by exposing the chest),and the difference was significant(t=3.615,P<0.05).On the other hand,the positioning error[(0.69±0.24)cm]of the"#-shaped"method was significantly lower than[(0.97±0.39)cm]of the"+-shaped"method for patients with thoracic tumor(fixed position of using thermoplastic film),and the difference also was significant(t=1.934,P<0.05).Conclusion:Compared to the conventional"+-shaped"method,the"#-shaped"method appears higher accuracy and repeatability during the positioning process of radiotherapy,which especially is suitable to the treatment for breast tumor and thoracic tumor that need accurately control the influences of respiratory motion.关键词
呼吸运动/放疗标记/胸部肿瘤/乳腺放疗Key words
Respiratory motion/Radiotherapy marking/Thoracic tumor/Radiotherapy on breast分类
医药卫生