测试技术学报2025,Vol.39Issue(5):524-530,7.DOI:10.62756/csjs.1671-7449.2025060
一种基于双轴转台温箱的加速度计温度标定补偿方法
A Temperature Calibration and Compensation Method for An Accelerometer Based on Dual-Axis Turntable Temperature Chamber
王月 1邱金娟 1杨小龙 1潘昊 1郅银周1
作者信息
- 1. 北京控制工程研究所,北京 100190||空间惯性测量技术实验室,北京 100190
- 折叠
摘要
Abstract
Inertial devices are the foundation of inertial systems,mainly including accelerometers and gyro-scopes.During the actual operation of an inertial navigation system,the inertial components will experi-ence changes in indicators such as zero bias and scale factor with changes in ambient temperature,which ultimately affect the initial alignment and navigation accuracy of the inertial navigation system.Among them,gyroscopes generally adopt temperature control measures to ensure adaptability to the full tempera-ture range,while accelerometers generally adopt temperature compensation technology for miniaturization and low power consumption considerations.To eliminate the influence of environmental temperature on the accuracy of the accelerometer,it is necessary to calibrate the zero bias and scale factor of the acceler-ometer within the full temperature working range of-25℃to 45℃,Automatic temperature calibration and compensation using a dual-axis turntable temperature box,find the mathematical laws related to tem-perature,establish a compensation mathematical model,and use this model for temperature compensa-tion.After temperature compensation,the output accuracy of the accelerometer can be improved by an order of magnitude,and the compensation effect is significant.关键词
双轴转台温箱/加速度计/温度标定与补偿Key words
dual-axis turntable temperature chamber/accelerometer/temperature calibration and compensation分类
航空航天引用本文复制引用
王月,邱金娟,杨小龙,潘昊,郅银周..一种基于双轴转台温箱的加速度计温度标定补偿方法[J].测试技术学报,2025,39(5):524-530,7.