| 注册
首页|期刊导航|广东电力|基于PMU电压选取的广域测量系统数据质量提升策略

基于PMU电压选取的广域测量系统数据质量提升策略

廖梦竹 徐飞阳 李娜 王志华 刘灏 刘勇

广东电力2025,Vol.38Issue(8):91-101,11.
广东电力2025,Vol.38Issue(8):91-101,11.DOI:10.3969/j.issn.1007-290X.2025.08.009

基于PMU电压选取的广域测量系统数据质量提升策略

Data Quality Improvement Strategy for Wide-area Measurement System based on PMU Voltage Selection

廖梦竹 1徐飞阳 2李娜 3王志华 4刘灏 1刘勇3

作者信息

  • 1. 华北电力大学 新能源电力系统全国重点实验室,北京 102206
  • 2. 国家电网有限公司华北分部,北京 100053
  • 3. 国网山东省电力公司,山东 济南 250001
  • 4. 北京四方继保工程技术有限公司,北京 100083
  • 折叠

摘要

Abstract

The synchronous Phasor Measurement Unit furnishes precise data for the monitoring of power grid operation.However,data quality problems have become increasingly prominent due to causes such as communication disruptions and equipment malfunctions.At a certain engineering site,abnormal power oscillation emerged in the data sent from the PMU to the main station.The analysis disclosed that the direct cause was the incorrect selection of bus voltage.The complex power grid configuration at the engineering site poses challenges to voltage selection.In this paper,the decision-making effects of each voltage selection scheme are quantitatively evaluated based on the Analytic Hierarchy Process,comprehensively considering the merits and demerits as well as the adaptability of the schemes.Eventually,it is recommended to employ a voltage switching device to select the bus voltage in specific scenarios.This device,by connecting to the disconnector of the primary equipment,automatically selects the optimal voltage source to ensure that the bus voltage synchronously switches along with the operation mode of the primary equipment,guaranteeing the accuracy and consistency of PMU data collection and thereby enhancing the data quality of PMU.The research findings provide scientific decision support for practical application scenarios related to bus voltage selection.Combined with the local power grid operation conditions,they offer effective solutions for improving data quality and optimizing power grid monitoring.

关键词

同步相量测量单元/数据质量/母线电压选取/电压切换装置/层次分析法

Key words

synchronized phasor measurement unit/data quality/bus voltage selection/voltage switching device/analytic hierarchy process

分类

信息技术与安全科学

引用本文复制引用

廖梦竹,徐飞阳,李娜,王志华,刘灏,刘勇..基于PMU电压选取的广域测量系统数据质量提升策略[J].广东电力,2025,38(8):91-101,11.

基金项目

国家电网有限公司科技项目(5100-202199530A-0-5-ZN,5211DS21N013) (5100-202199530A-0-5-ZN,5211DS21N013)

广东电力

OA北大核心

1007-290X

访问量0
|
下载量0
段落导航相关论文