| 注册
首页|期刊导航|东北电力技术|600 MW墙式切圆褐煤机组汽温偏差优化研究

600 MW墙式切圆褐煤机组汽温偏差优化研究

李含琼 王博 徐向龙 王溪聆 张显铭

东北电力技术2025,Vol.46Issue(9):42-46,5.
东北电力技术2025,Vol.46Issue(9):42-46,5.

600 MW墙式切圆褐煤机组汽温偏差优化研究

Research on Steam Temperature Deviation Optimization of 600 MW Wall-Type Tangential-Fired Lignite Unit

李含琼 1王博 1徐向龙 2王溪聆 2张显铭2

作者信息

  • 1. 辽宁东科电力有限公司,辽宁 沈阳 110179
  • 2. 华能国际电力有限公司丹东电厂,辽宁 丹东 118300
  • 折叠

摘要

Abstract

When a 600 MW wall-type tangential-fired lignite boiler in a certain power plant is operating at a load of 300 MW,there are significant deviations in the main steam temperature on both sides and in the desuperheating water volume.Through a series of ba-sic tests to research the boiler·s operating status,it analyzes the causes of the steam temperature deviation,and summarizes the most effective adjustment strategies and methods under the existing conditions.According to the deviation of the main steam temperature,it conductes tests on the horizontal swing angle of the overfire air and the secondary air offset respectively in response to the main steam temperature deviation.It adjusts the flue gas heat load to be relatively uniform,thereby reducing the main steam temperature deviation and the desuperheating water volume deviation.Based on the test results,it puts forward reasonable suggestions to provide a reference for boilers with similar problems.

关键词

墙式切圆/汽温偏差/减温水/优化

Key words

wall-type tangential/steam temperature deviation/desuperheating water/optimization

分类

信息技术与安全科学

引用本文复制引用

李含琼,王博,徐向龙,王溪聆,张显铭..600 MW墙式切圆褐煤机组汽温偏差优化研究[J].东北电力技术,2025,46(9):42-46,5.

东北电力技术

1004-7913

访问量0
|
下载量0
段落导航相关论文