| 注册
首页|期刊导航|色谱|碳纳米管复合微球材料结合固相微萃取-气相色谱-串联质谱法检测环境水样中痕量多氯联苯

碳纳米管复合微球材料结合固相微萃取-气相色谱-串联质谱法检测环境水样中痕量多氯联苯

宋新力 朱淑琪 武玉心 仲丽艳 刘雨晴

色谱2025,Vol.43Issue(10):1154-1161,8.
色谱2025,Vol.43Issue(10):1154-1161,8.DOI:10.3724/SP.J.1123.2025.01004

碳纳米管复合微球材料结合固相微萃取-气相色谱-串联质谱法检测环境水样中痕量多氯联苯

Determination of trace polychlorinated biphenyls in environmental water samples by solid-phase microextraction-gas chromatography-tandem mass spectrometry using carbon nanotube composite microspheres materials

宋新力 1朱淑琪 1武玉心 1仲丽艳 1刘雨晴1

作者信息

  • 1. 枣庄学院食品科学与制药工程学院,山东 枣庄 277160
  • 折叠

摘要

Abstract

Polychlorinated biphenyls(PCBs)pose serious threats to the environment and human health because they are among the most common and persistent organic pollutants globally.In this study,six PCBs were extracted from environmental water samples using multiwalled carbon nanotubes(MWCNTs)on polystyrene(PS)microspheres as the solid-phase microextraction(SPME)coating material for gas chromatography-tandem mass spectrometry(GC-MS/MS).This coating material is highly stable and exhibited a high extraction efficiency.2,2′,5,5′-Tetrachlorobiphenyl(PCB-52),2,2′,4,5,5′-pentachlorobiphenyl(PCB-101),2,3′,4,4′,5-pentachlorobiphenyl(PCB-118),2,2′,3,4,4′,5′-hexachlorobiphenyl(PCB-138),2,2′,4,4′,5,5′-hexachlorobiphenyl(PCB-153)and 2,2′,3,4,4′,5,5′-heptachlorobiphenyl(PCB-180)were chosen as target analytes.The main extraction factors were optimized using a single-factor optimization method,which led to the following optimum extraction conditions:adsorption time,50 min;agitation speed,600 r/min;pH,6;NaCl concentration,1.5 mol/L;desorption temperature,280 ℃;and desorption time,4 min.GC coupled with triple quadrupole mass spectrometry was used to quantify PCBs in water samples.The chromatographic separation system was equipped with a TG-5 SILMS column(30 m×0.25 mm×0.25 μm),with electron impact ionization and multi-reaction monitoring modes used during mass spectrometry.Five batches of MWCNT@PS were used as SPME coating materials,which were determined to have relative standard deviations(RSD)of less than 8.8%for the six PCBs.The reusability of the MWCNT@PS coating was also investigated;RSD of the recoveries of 2.8%‒9.3%were obtained after ten SPME cycles with the same coating.These results reveal that the MWCNT@PS coating materials are highly stable and reusable in SPME applications,with good results obtained under the optimal conditions.The established method exhibited linearity in the range of 0.03‒1 000 ng/L for PCB-52 and PCB101,0.07‒1 000 ng/L for PCB118,PCB138,and PCB 153,and 0.10‒1 000 ng/L for PCB-180,with correlation coefficients of 0.993-0.998.Limits of detection and quantification(LODs and LOQs,respectively)of 0.01‒0.03 and 0.03‒0.10 ng/L were determined for the developed method.The intra-and inter-day precisions exhibited RSDs of 1.64%‒8.16%and 2.83%‒8.41%,respectively,at 2 ng/L,3.31%‒7.19%and 3.79%‒9.12%,respectively,at 10 ng/L,and 2.70%‒9.38%and 4.04%‒8.56%,respectively,at 100 ng/L.The established method was used to determine six PCBs in barreled drinking water,rainwater,and three environmental river water samples.No PCBs were found in barreled drinking water,rain water and river water.Satisfactory recoveries of 82.4%-113.2%were achieved at low,medium,and high levels.Accordingly,the MWCNT@PS-composite-coating-material-based SPME-GC-MS/MS method is accurate and effective.This study revealed that MWCNT@PS composites provide a good avenue for the rapid and sensitive detection of PCBs in water samples.

关键词

碳纳米管复合微球材料/固相微萃取/气相色谱-串联质谱/多氯联苯/环境水样

Key words

carbon nanotube composite microspheres materials/solid-phase microextraction(SPME)/gas chromatography-tandem mass spectrometry(GC-MS/MS)/polychlorinated biphe-nyls(PCBs)/environmental water sample

分类

化学化工

引用本文复制引用

宋新力,朱淑琪,武玉心,仲丽艳,刘雨晴..碳纳米管复合微球材料结合固相微萃取-气相色谱-串联质谱法检测环境水样中痕量多氯联苯[J].色谱,2025,43(10):1154-1161,8.

基金项目

山东省枣庄市科技计划项目(2021GX09).Scientific and Technological Plan Projects of Zaozhuang City,Shandong Province(No.2021GX09). (2021GX09)

色谱

OA北大核心

1000-8713

访问量0
|
下载量0
段落导航相关论文