抽水蓄能电站厂房振动问题分析及对策

王胜军 张飞 赵毅锋 任绍成 李刚

长江科学院院报2025,Vol.42Issue(9):174-184,11.
长江科学院院报2025,Vol.42Issue(9):174-184,11.DOI:10.11988/ckyyb.20240698

抽水蓄能电站厂房振动问题分析及对策

Analysis and Solutions for Powerhouse Vibration in Pumped Storage Power Stations

王胜军 1张飞 2赵毅锋 3任绍成 4李刚5

作者信息

  • 1. 国网新源集团有限公司,北京 100052
  • 2. 国网电力工程研究院有限公司,北京 100069||国网新源控股有限公司抽水蓄能技术经济研究院,北京 100761
  • 3. 国网电力工程研究院有限公司,北京 100069
  • 4. 中国水利水电科学研究院,北京 100038
  • 5. 中国电建集团北京勘测设计研究院有限公司,北京 100024
  • 折叠

摘要

Abstract

[Objective]With the implementation of China's dual-carbon strategy,pumped storage has become in-creasingly important in the new-type power system dominated by renewable energy resources.As the operating inten-sity of pumped storage units continues to increase,vibration problems of pumped storage powerhouses have become increasingly common.It is necessary to summarize solutions to vibration problems in operating pumped storage pow-er stations and units to guide the design of future stations.[Methods]This study presented the identification of vi-bration sources and solutions to vibration issues of pumped storage power stations in Zhanghewan,Heimifeng,and Guangzhou.Two widely used structural design schemes for pumped storage powerhouses-thick-plate continuous wall structure and plate-girder frame structure-were presented,with a discussion of their advantages and disadvan-tages.Based on the actual cases,the layout of vibration measurement points for both the powerhouse and the unit was provided.Test methods and evaluation indicators were established for powerhouse vibration.[Results]Three typical methods for alleviating vibration in the powerhouse and pumped storage unit were proposed:controlling the energy generated by hydraulic excitation sources,staggering the frequencies between stationary parts and hydraulic excitation sources,improving the local or overall stiffness of structures.For structure stiffness and vibration resist-ance,the thick-plate continuous wall structure and plate-girder frame structure showed no significant difference.For the measurement and calculation of powerhouse vibration,more attentions should be paid to individual structural components to prevent local resonance with hydraulic excitation sources.[Conclusion]Both the thick-plate contin-uous wall structure and plate-girder frame structure can be widely used for pumped storage power stations,depen-ding on specific engineering requirements.The natural frequencies of overall and local powerhouse structures should maintain a frequency deviation of 20%from hydraulic excitation source frequencies.If the vibration velocity is used as an evaluation indicator,the maximum vibration values should be less than 10 mm/s on the powerhouse floor and 5 mm/s in the pit.This study provides important guidance for improving the structural design of pumped storage power stations in China.

关键词

抽水蓄能/厂房振动/厚板连续墙结构/板梁框架结构/振动测试/安全评价

Key words

pumped storage/powerhouse vibration/thick-plate continuous wall structure/plate-girder frame struc-ture/vibration testing/safety evaluation

分类

建筑与水利

引用本文复制引用

王胜军,张飞,赵毅锋,任绍成,李刚..抽水蓄能电站厂房振动问题分析及对策[J].长江科学院院报,2025,42(9):174-184,11.

基金项目

国家电网公司总部科技项目(5419-202243054A-1-1-ZN) (5419-202243054A-1-1-ZN)