| 注册
首页|期刊导航|实验流体力学|1.2 m大视场聚焦纹影技术

1.2 m大视场聚焦纹影技术

谢爱民 邢彦昌 王敏 部绍清

实验流体力学2025,Vol.39Issue(4):48-54,7.
实验流体力学2025,Vol.39Issue(4):48-54,7.DOI:10.11729/syltlx20220047

1.2 m大视场聚焦纹影技术

1.2 m large-field focusing schlieren technique

谢爱民 1邢彦昌 1王敏 2部绍清1

作者信息

  • 1. 中国空气动力研究与发展中心 超高速空气动力研究所,绵阳 621000
  • 2. 中国兵器装备集团自动化研究所,绵阳 621000
  • 折叠

摘要

Abstract

In the conventional"Z"structure schlieren technique,due to the limitation of large-size optical element materials and processing technology,the size of the test field is usually less than 1 meter.In order to show the flow field of a large-scale model in a wind tunnel,the focusing schlieren technique is proposed to show the flow field in the 1.2 m test area.According to the imaging principle,the large size Fresnel lens are replaced by a matrix light source.After solving the key technologies such as the engineering design of large-size light source splicing,the development of large-diameter focusing lens and the production of high-definition imaging screen,two sets of focusing schlieren systems with the test field of view of 1.2 m×1.2 m were established,and the schlieren images of the hypervelocity flow field with high sensitivity were obtained in the wind tunnel.The flow visualization with larger field is expected to be realized through the splicing of larger size light sources.

关键词

聚焦纹影/流动显示/纹影/大视场/LED光源

Key words

focusing schlieren/flow visualization/schlieren/large field/LED light source

分类

航空航天

引用本文复制引用

谢爱民,邢彦昌,王敏,部绍清..1.2 m大视场聚焦纹影技术[J].实验流体力学,2025,39(4):48-54,7.

实验流体力学

OA北大核心

1672-9897

访问量0
|
下载量0
段落导航相关论文