| 注册
首页|期刊导航|重庆大学学报|基于多目标优化的双层天窗采透光系统设计

基于多目标优化的双层天窗采透光系统设计

侯万钧 申开兴 席晖

重庆大学学报2025,Vol.48Issue(9):76-92,17.
重庆大学学报2025,Vol.48Issue(9):76-92,17.DOI:10.11835/j.issn.1000-582X.2025.09.008

基于多目标优化的双层天窗采透光系统设计

Design of a double-layer skylight light transmission system based on multi-objective optimization

侯万钧 1申开兴 2席晖1

作者信息

  • 1. 河北工程大学 建筑与艺术学院,河北 邯郸 056000||天津大学 建筑学院,天津 300072
  • 2. 河北工程大学 建筑与艺术学院,河北 邯郸 056000
  • 折叠

摘要

Abstract

The incorporation of skylights significantly improves indoor natural lighting uniformity and illumination levels.Additionally,the use of an air layer helps mitigate hear transfer between indoor and outdoor environments,thereby improving the overall quality of the indoor light environment.Using a comprehensive market building in Handan City as a case study,this research designs a double-layer skylight transmission system comprising 27 combination configurations by integrating skylights and air layers through the Grasshopper simulation platform.With the help of Octopus,a multi-objective optimization solution is developed to balance energy consumption and light comfort.The independent variables and evaluation index datasets are further analyzed using the Hiplot platform to evaluate correlations between design parameters and light environment indicators.Results show that the optimal configuration is achieved when the air layer thickness is 0.8 m,the semi-transparent material thickness is 0.005 m,and the skylight area ratio is 0.3.Under these conditions,the proportion of indoor effective daylight illumination increases by 10.97%,the probability of daytime glare decreases by 39.40%,the brightness ratio between north-south entrances and exits and their background surfaces decreases by 61.45%and 45.10%respectively,and energy consumption per unit area is decreased by 18.42%.Correlation analysis reveals that interlayer height is negatively correlated with daylight coefficient,effective daylight illumination,and daytime glare probability,although these correlations are weak.The skylight area ratio is negatively correlated with indoor effective daylight illumination,while the thickness of the interior light-transmitting panel is positively and strongly correlated with daytime glare probability.Finally,the system's economic viability,applicability,and feasibility are analyzed,offering a novel design approach and component model for enhancing the indoor light environment of large-scale public buildings in urban settings.

关键词

双层天窗采透光系统/多目标优化/室内光环境/相关性分析

Key words

double-layer skylight light transmission system/multi-objective optimization/indoor light environment/correlation analysis

分类

建筑与水利

引用本文复制引用

侯万钧,申开兴,席晖..基于多目标优化的双层天窗采透光系统设计[J].重庆大学学报,2025,48(9):76-92,17.

基金项目

河北省自然科学基金面上项目(E2025402020).Supported Natural Science Foundation of Heibei Province of China(E2025402020). (E2025402020)

重庆大学学报

OA北大核心

1000-582X

访问量0
|
下载量0
段落导航相关论文