家电科技2025,Vol.4Issue(4):120-123,4.DOI:10.19784/j.cnki.issn1672-0172.2025.04.021
挂机导风板凝露仿真模型建立及案例研究
Case study and simulation model of the condensation of the wind deflector
李同琴 1陈守海 2邱子岳 1王相乾 1龚连发1
作者信息
- 1. 海信家电集团股份有限公司 山东 青岛 266100
- 2. 海信空调有限公司 山东 青岛 266100
- 折叠
摘要
Abstract
When the household air-conditioner is running in the high humidity environment in summer,the condensation and dripping of the wind deflector occurs,which causes significant inconvenience to the user.In order to quantify the evaluation method of wind deflector condensation,proposes a wind deflector condensation simulation method based on dehumidification model,and carries out the wind deflector condensation prediction analysis of a certain model of home empty hang-up machine.The results show that the condensation simulation method used can predict the condensation location well,and the condensation dripping risk at the bottom of the guide plate can be greatly improved by optimizing the contour line at the bottom of the large guide plate and matching the design with the air duct contour line.关键词
除湿模型/凝露仿真方法/凝露位置/凝露速率Key words
Dehumidification model/Condensation simulation method/Condensation location/Dew condensation rate分类
信息技术与安全科学引用本文复制引用
李同琴,陈守海,邱子岳,王相乾,龚连发..挂机导风板凝露仿真模型建立及案例研究[J].家电科技,2025,4(4):120-123,4.