Abstract
An abnormal clutter appeared in a copper alloy during eddy current testing.The causes of clutter were analyzed by means of macroscopic observation,chemical composition analysis,residual stress test,metallographic examination and hardness test.The results show that there was a large residual stress in the material.The residual stress changed the conductivity of the local area on the surface of the material and caused the change of the eddy current detection signal.The residual stress could be reduced by means of stress relief annealing and straightening process adjustment,and the clutter phenomenon in eddy current testing could be improved.关键词
残余应力/涡流检测/电导率/杂波/铜合金Key words
residual stress/eddy current testing/conductivity/clutter/copper alloy分类
矿业与冶金引用本文复制引用
彭建章,姚联..铜合金涡流检测异常杂波产生原因[J].理化检验-物理分册,2025,61(9):18-20,3.