中国资源综合利用2025,Vol.43Issue(9):251-253,3.DOI:10.3969/j.issn.1008-9500.2025.09.073
基于调蓄功能的污水处理厂工程设计及运行分析
Engineering Design and Operation Analysis of Sewage Treatment Plant Based on Regulating and Storage Function
朱有光1
作者信息
- 1. 深圳市深水龙塘沟水质净化有限公司,广东 深圳 518000
- 折叠
摘要
Abstract
During the initial light rain period,the amount of mixed rainwater and sewage in the river suddenly increases,the regulating and storage tank plays a role in source collection,process regulation,and water volume adjustment,and the collected rainwater and sewage mixed water is purified and treated by the terminal sewage treatment plant.Taking a certain sewage treatment plant as an example,the detailed introduction is provided to the process design and characteristics of each unit,based on the seasonal changes in sewage volume and quality in the regulating and storage tank,different operating plans are formulated for different working conditions.The actual operation results show that the sewage treatment plant operates stably,and the main indicators of the effluent meet the Class Ⅳ water standard of the Environmental Quality Standards for Surface Water(GB 3838-2002),which can provide reference for the design and operation of similar sewage treatment plants.关键词
污水处理厂/调蓄池/工程设计Key words
sewage treatment plant/regulating and storage tank/engineering design分类
资源环境引用本文复制引用
朱有光..基于调蓄功能的污水处理厂工程设计及运行分析[J].中国资源综合利用,2025,43(9):251-253,3.