能源研究与管理2025,Vol.17Issue(3):59-63,72,6.DOI:10.16056/j.2096-7705.2025.03.009
某核电站凝汽器半侧运行机组功率控制策略
Power Control Strategy of Condenser Half-Side Operating of Nuclear Power Plant
摘要
Abstract
For CPR1000 units operating under half-side condenser conditions,reactor power is conventionally regulated below 60%full power(FP).However,inherent contradictions exist between the minimum power plateau required for delta-Ⅰ axial flux difference control and the maximum permissible plateau ensuring condenser tube integrity.Adhering to the nuclear safety conservative decision-making principle,this study employs three evaluation models-status factor,load factor,and risk coeffi-cient-to assess operational risks during half-side condenser operation at a reference plant,subsequently proposing corres-ponding safety margin enhancements.Integrating empirical operating conditions,we developed an optimized power control strategy for half-side condenser scenarios with defined mitigation protocols for safety criterion deviations.Implementation assessments across Phase Ⅰ and Ⅱ units demonstrate that,electrical power regulation must dynamically accommodate circula-ting water temperature variations.When operational stability proves unattainable,controlled air admittance elevates condenser backpressure,thereby safeguarding cooling tube integrity.This methodology establishes an operational paradigm for congen-eric CPR1000 units conducting half-side condenser maneuvers.关键词
凝汽器/半侧运行/机组功率/状态因子Key words
condenser/half-side operation/unit power/state factor分类
信息技术与安全科学引用本文复制引用
王建国,赵清森,陈余佳,张鼎,陈杰..某核电站凝汽器半侧运行机组功率控制策略[J].能源研究与管理,2025,17(3):59-63,72,6.基金项目
中广核集团尖峰计划项目(R-2024SZSO71TF) (R-2024SZSO71TF)