电瓷避雷器Issue(5):10-16,7.DOI:10.16188/j.isa.1003-8337.2025.05.002
海上风机雷电过电压及其防护措施研究
Lightning Overvoltage and Protection Measures for Offshore Wind Turbines
摘要
Abstract
The complex marine environment makes the transient overvoltage caused by lightning strike on wind turbine blades more prominent,which puts higher requirements for the reliability and effectiveness of lightning protection system.The current research on lightning protection only focuses on the first light-ning strike,and only observes the potential rise of the blade,tower and grounding device,but ignores the potential rise of the electrical part in the engine room,especially on both sides of the engine room trans-former.By building a lightning strike transient integration model of the offshore wind turbine in the ATP-EMTP software,the author analyzes the transient process of the engine room transformer after the blades are subject to the second lightning strike,as well as the lightning protection effect after connecting SPD and arrester,providing a basis for lightning protection and insulation coordination of the offshore wind turbine.关键词
海上风机/二次雷击/机舱变压器/暂态响应Key words
offshore wind turbine/the second lightning strike/engine room transformer/transient re-sponse引用本文复制引用
王士琪,詹花茂..海上风机雷电过电压及其防护措施研究[J].电瓷避雷器,2025,(5):10-16,7.基金项目
大规模海上风电并网系统关键设备及运行控制(编号:HNKJ20-H88-02).Project supported by Key Equipment and Operation Control of Large-Scale Offshore Wind Power Grid Connection System(No.HNKJ20-H88-02). (编号:HNKJ20-H88-02)