电力系统及其自动化学报2025,Vol.37Issue(10):150-158,9.DOI:10.19635/j.cnki.csu-epsa.001447
考虑多支路同时跳闸的静态安全灵敏度计算
Static Safety Sensitivity Calculation Considering Simultaneous Tripping of Multiple Branches
范翔 1赵维兴 1苏寅生2
作者信息
- 1. 贵州省电网公司电力调度控制中心,贵阳 550002
- 2. 南方电网电力调度控制中心,广州 510000
- 折叠
摘要
Abstract
The existing static safety sensitivity techniques are all applied to analyze the impact of one single branch on the power flow of another branch.In this paper,a sensitivity technique is studied,with which the impact of simultane-ous tripping of multiple branches on the power flow of one single branch is analyzed.First,the calculation of sensitivity factors for multiple branches is converted into the calculation of sensitivity factors for one single branch under some spe-cific grid structures,and it is further extended to scenarios of 220 kV bus and 500 kV bus tripping.The obtained sensi-tivity factors have a clear physical meaning and low computational complexity.Second,for the convenience of cross-sec-tion control,the concept of cross-section sensitivity factor and its calculation method are proposed,which has a clear physical meaning and simple calculation.Finally,the simplicity of the proposed sensitivity algorithm and the accuracy of power flow control are verified through numerical examples.关键词
静态安全灵敏度技术/多支路灵敏度/220千伏母线跳闸/500千伏母线跳闸/断面/断面灵敏度Key words
static safety sensitivity technique/multi-branch sensitivity/220 kV bus tripping/500 kV bus tripping/cross-section/cross-section sensitivity分类
动力与电气工程引用本文复制引用