| 注册
首页|期刊导航|解放军医学院学报|不同表面处理的骨整合经皮假体的细胞毒性及对植入后兔背部位感染预防及愈合效果的研究

不同表面处理的骨整合经皮假体的细胞毒性及对植入后兔背部位感染预防及愈合效果的研究

朱庆岩 许猛 赵雪林 廖松 郭子轩 赵子仪 王振 王梓颖 黄子福 曹城玮

解放军医学院学报2025,Vol.46Issue(6):623-630,封3,9.
解放军医学院学报2025,Vol.46Issue(6):623-630,封3,9.DOI:10.12435/j.issn.2095-5227.25030201

不同表面处理的骨整合经皮假体的细胞毒性及对植入后兔背部位感染预防及愈合效果的研究

Cytotoxicity of osteointegrated percutaneous prostheses with different surface treatments and their effects on prevention and healing of posterior infection in rabbits

朱庆岩 1许猛 2赵雪林 2廖松 2郭子轩 2赵子仪 2王振 1王梓颖 1黄子福 1曹城玮1

作者信息

  • 1. 解放军医学院,北京 100853
  • 2. 解放军总医院第四医学中心骨科医学部骨肿瘤科,北京 100037
  • 折叠

摘要

Abstract

Background Osseointegration prostheses can directly transfer the load to the bone through the skin,which has certain advantages compared with traditional prosthetic sockets.However,they generally face the risk of infection caused by the unsealing of the soft tissue in the percutaneous part.Objective To fabricate percutaneous prostheses via mechanical machining methods and apply distinct surface treatments to investigate their biological impacts,infection-resistant properties,and integration performance with soft tissues at transcutaneous interfaces.Methods Thirty-six experimental percutaneous prostheses were prepared by machining and were randomly divided into groups A,B,C,D,E,and F,with 6 in each group.The surface of groups A and E were treated by sandblasting+TiNbN coating,polishing+TiNbN coating,high polishing,sandblasting+micro-arc oxidation,and acid etching,while the surface of group F was not treated.The effects of different percutaneous prosthesis extracts on MC3T3-E1 were analyzed using the MTT method.Eighteen New Zealand white rabbits were randomly divided into 6 groups,with 3 rabbits in each group.Two prostheses with the same surface treatment were implanted in the symmetrical part of the back of each experimental animal.The skin growth and recovery of the surgical site of the experimental animals were observed.At the same time,the white blood cell count,neutrophil count,platelet count,hemoglobin,alanine aminotransferase,creatinine,complement component 3,and complement component 4 were detected at different time points,and the effects of percutaneous prostheses with different surface treatments on hematological indexes of rabbits were analyzed.Finally,the liver,kidney tissue,and percutaneous materials were taken for histological examination.Results The results of the MTT assay showed that there was no significant difference in cell survival rate between the experimental groups and the control group(P>0.05).There was no significant difference in platelet count,hemoglobin,alanine aminotransferase,and creatinine in the same group at different time points after operation(P>0.05).On the 28th postoperative day,the WBC count in group B was lower than that in group F(P=0.019),and on the 42nd postoperative day,WBC counts in group A was lower than that in group F(P=0.002),groups B,C,D,E(P<0.001).The level of complement component 3 in group B was lower than that in group F(P=0.039).On the 28th day after operation,the level of complement C4 in group B was lower than that in group A(P=0.009)and group E(P=0.006).There was no obvious degeneration,necrosis,or inflammatory changes in liver and kidney tissue sections.The histological examination of the percutaneous site showed that the percutaneous prosthesis treated with polishing and titanium-niobium-nitrogen coating was closely attached to the surrounding soft tissue.Conclusion Percutaneous prostheses with different surface treatments demonstrates biosafety without causing significant tissue damage.Untreated surface prostheses exhibits lower infection resistance,while those subjected to polishing combined with TiNbN coating treatment shows enhanced antimicrobial efficacy and achieves more robust integration with surrounding soft tissues.This optimized surface modification protocol holds clinical potential as a transcutaneous interface processing technique for osseointegrated prostheses.

关键词

骨整合/感染/假体和植入物/生物膜/生物相容性/涂层

Key words

bone integration/infection/prostheses and implants/biofilm/biocompatibility/coating

分类

医药卫生

引用本文复制引用

朱庆岩,许猛,赵雪林,廖松,郭子轩,赵子仪,王振,王梓颖,黄子福,曹城玮..不同表面处理的骨整合经皮假体的细胞毒性及对植入后兔背部位感染预防及愈合效果的研究[J].解放军医学院学报,2025,46(6):623-630,封3,9.

解放军医学院学报

2095-5227

访问量4
|
下载量0
段落导航相关论文