| 注册
首页|期刊导航|广东电力|基于IEC 60287标准的XLPE高压直流海底电缆热老化条件下载流量计算修正

基于IEC 60287标准的XLPE高压直流海底电缆热老化条件下载流量计算修正

于是乎 李林恒 李银格 余欣 张伟超

广东电力2025,Vol.38Issue(11):95-102,8.
广东电力2025,Vol.38Issue(11):95-102,8.DOI:10.3969/j.issn.1007-290X.2025.11.010

基于IEC 60287标准的XLPE高压直流海底电缆热老化条件下载流量计算修正

Modified Ampacity Calculation for XLPE HVDC Submarine Cables Under Thermal Aging Conditions Based on IEC 60287 Standard

于是乎 1李林恒 2李银格 1余欣 1张伟超2

作者信息

  • 1. 广东电网有限责任公司电力科学研究院 广东省电力装备可靠性重点实验室,广东 广州 510080
  • 2. 哈尔滨理工大学电气与电子工程学院,黑龙江 哈尔滨 150080
  • 折叠

摘要

Abstract

Currently,the rated current-carrying capacity of cables is statically calculated based on the IEC 60287 standard.However,the actual current-carrying capacity of operational cables dynamically varies with ambient temperature,and the coupling relationship between the conductivity of the insulation material and temperature in HVDC submarine cables further affects the capacity calculation.To address this,this study modifies the IEC 60287 based calculation model for the current-carrying capacity of HVDC submarine cables under long-term service conditions.Firstly,the accelerated thermal aging tests were conducted to clarify the degradation evolution of the thermal conductivity of cross-linked polyethylene(XLPE)with temperature gradient and aging duration.Time-varying functions of XLPE thermal conductivity at 135℃,150℃,and 175℃ were determined based on first-order kinetics.Subsequently,an equivalent time conversion model using the Arrhenius principle was proposed to translate the thermal aging time of XLPE at 135℃ to equivalent conditions at 70℃.Combined with the time-varying thermal conductivity function,a degradation model for the thermal conductivity of HVDC submarine cable insulation was established.Finally,a modified model for calculating the current-carrying capacity of DC submarine cables,considering the time-varying characteristics of material parameters,was developed and validated against finite element multiphysics simulations.It is proved the modified model effectively compensates for calculation deviations caused by thermal conductivity degradation,with a discrepancy of less than 0.1%compared to numerical simulation results,providing a theoretical basis and technical support for enhancing the operational safety and transmission efficiency of submarine cables.

关键词

交联聚乙烯/高压直流/海底电缆/IEC 60287/热导率/载流量

Key words

cross linked polyethylene(XLPE)/high voltage direct current/submarine cable/IEC 60287/thermal conductivity/current carrying capacity

分类