| 注册
首页|期刊导航|东北电力技术|1000MW超超临界锅炉中间点焓值校正方法研究

1000MW超超临界锅炉中间点焓值校正方法研究

刘彦硕 田帅 牛小辉

东北电力技术2025,Vol.46Issue(12):30-34,39,6.
东北电力技术2025,Vol.46Issue(12):30-34,39,6.

1000MW超超临界锅炉中间点焓值校正方法研究

Research on Correction Method for Intermediate Point Enthalpy of 1000 MW Ultra Supercritical Boiler

刘彦硕 1田帅 1牛小辉1

作者信息

  • 1. 山东能源集团灵台火力发电有限公司,甘肃 平凉 744400
  • 折叠

摘要

Abstract

Based on the dynamic adjustment method of enthalpy increase deviation,the boiler operating conditions change due to in-ternal and external disturbances of the unit,which makes it difficult to respond quickly and accurately.This often leads to problems such as untimely or inaccurate calibration of operating parameters.The intermediate point enthalpy is a key parameter reflecting the in-ternal steam water separation and heat transfer status of the boiler.By accurately correcting this parameter,any factors that may affect the stability of the boiler can be detected and adjusted in a timely manner,ensuring the stable,safe,and efficient operation of the boiler under different loads.Therefore,it proposes a method for correcting the intermediate point enthalpy in a 1000 MW ultra super-critical boiler based on the conservation of mass and energy.It constructs a dynamic operation model of the boiler.By accurately cal-culating key parameters such as feedwater flow rate,main steam flow rate,and heat absorbed by the working fluid from the outside,it selects the steam water separator outlet separator as the middle position of the boiler,which is the key monitoring point,to accurately monitor the enthalpy value of micro superheated steam.Taking into account the influence of the flow rate of the desuperheating water in the superheater,it obtains the intermediate point enthalpy of the separator outlet through calculation and correction.To ensure accu-rate correction of the intermediate point enthalpy,it takes the enthalpy increase of the water-cooled wall as the key monitoring indica-tor.It dynamically adjusts the fuel supply and water supply based on the enthalpy increase deviation,while the coal water ratio and cooling water flow rate are adjusted accordingly to achieve dynamic correction of the intermediate point enthalpy.The experimental re-sults show that the proposed research method can perform well in terms of enthalpy control accuracy,enthalpy fluctuation range,and enthalpy correction speed,improving the operational economy of the boiler system and the overall efficiency of the boiler.

关键词

1000MW超超临界锅炉/中间点焓值/汽水分离器出口/焓值设定/焓值校正

Key words

1000 MW ultra supercritical boiler/intermediate point enthalpy/steam water separator outlet/enthalpy value setting/enthalpy correction

分类

信息技术与安全科学

引用本文复制引用

刘彦硕,田帅,牛小辉..1000MW超超临界锅炉中间点焓值校正方法研究[J].东北电力技术,2025,46(12):30-34,39,6.

东北电力技术

1004-7913

访问量0
|
下载量0
段落导航相关论文