首页|期刊导航|高电压技术|基于线模故障分量电流积分的柔性直流配电网线路保护方案

基于线模故障分量电流积分的柔性直流配电网线路保护方案

WEI Xiuyan ZOU Guibin WANG Zhenhua ZHANG Shuo LI Junhui

高电压技术2025,Vol.51Issue(12):6044-6052,9.
高电压技术2025,Vol.51Issue(12):6044-6052,9.DOI:10.13336/j.1003-6520.hve.20241798

基于线模故障分量电流积分的柔性直流配电网线路保护方案

Line-mode Fault Component Current Integration Based Line Protection for Flexible DC Distribution Grid

WEI Xiuyan 1ZOU Guibin 1WANG Zhenhua 2ZHANG Shuo 3LI Junhui4

作者信息

  • 1. School of Electrical Engineering,Shandong University,Jinan 250061,China
  • 2. Dongfang Electric Corporation Limited,Yantai 264000,China
  • 3. School of Control Science and Engineering,Shandong University,Jinan 250061,China
  • 4. Key Laboratory of Modern Power System Simulation and Control&Renewable Energy Technology,Ministry of Education(Northeast Electric Power University),Jilin 132012,China
  • 折叠

摘要

Abstract

When the pole-to-pole fault occurs at the line of a flexible DC distribution grid,the fault current will rise quickly to a high peak value,which will seriously threat to the fragile power electronic components in the system,leading to MMC blocks.However,the existing protections have the problem of weak ability to identify the high resistance fault,resulting in reduced reliability and selectivity.In order to solve the above problems,a protection based on the line-mode fault component current(LFCC)integration is proposed.Firstly,the expression of LFCC under the internal and external faults is theoretically analyzed.It can be analyzed that the amplitude of the LFCC increases rapidly after the fault,and the polarity is related to the fault direction.Thus,the fault identification criterion is constructed by the LFCC.Only by apply-ing the local information can the metallic fault be quickly identified,and the internal high resistance fault can be identified by integrating the fault direction information on the other line end.Finally,the PSCAD is applied to verify the proposed protection.Extensive simulation results prove that the protection has fast speed and high sensitivity,and is robust to high resistance fault.

关键词

柔性直流配电网/线模故障分量电流/线路保护/故障识别/过渡电阻

Key words

flexible DC distribution grid/line-mode fault component current/line protection/fault identification/fault resistance

引用本文复制引用

WEI Xiuyan,ZOU Guibin,WANG Zhenhua,ZHANG Shuo,LI Junhui..基于线模故障分量电流积分的柔性直流配电网线路保护方案[J].高电压技术,2025,51(12):6044-6052,9.

基金项目

现代电力系统仿真控制与绿色电能新技术教育部重点实验室(东北电力大学)开放课题(MPSS2024-06). Project supported by Key Laboratory of Modern Power System Simulation and Control&Renewable Energy Technology(Northeast Electric Power University)Open Fund(MPSS2024-06). (东北电力大学)