南京医科大学学报(自然科学版)2026,Vol.46Issue(1):77-81,93,6.DOI:10.7655/NYDXBNSN250836
采用手术肩枕改善甲状腺CT图像质量的应用研究
Application study on improving thyroid CT image quality using surgical shoulder pillow
摘要
Abstract
Objective:To investigate the value of a modified position utilizing surgical shoulder pillows in optimising the quality of thyroid CT images.Methods:A total of 176 patients with thyroid nodules who were scheduled for CT examination were prospectively enrolled,and divided into a control group(conventional position,n=88)and an experimental group(modified position,n=88).The patients in the control group were positioned in the supine position with their arms on each side of their bodies and drooping naturally.The experimental group was adopted with the shoulders elevated by the surgical shoulder pillows,shoulders parallel to the upper edge of the shoulder pillows,arms placed on each side of the body,and the head in the hyperextension position.The subjective quality scores(overall image quality,subjective noise evaluation,artefacts),the objective quality scores(signal-to-noise ratio SNR,contrast-to-noise ratio CNR),and the radiation doses[CT dose index(volume computed tomography dose index,CTDIvol),dose-length product(DLP),effective dose(ED)]of arterial-phase and venous-phase CT images were compared between the two groups.Results:The experimental group outperformed the control group in subjective picture quality scores,demonstrating superiority in overall image quality(Z=-5.385,P<0.001),subjective noise(Z=-5.609,P<0.001),and artefact suppression(Z=-3.473,P=0.001).The experimental group exhibited much superior SNR and CNR than the control group in both arterial(SNR:Z=-6.533;CNR:Z=-6.475;both P<0.001)and venous phases(SNR:t=-7.193;CNR:Z=-5.705;both P<0.001).No significant differences in radiation dose were observed between the experimental and control groups for arterial phase CTDIvol(Z=-0.527,P=0.598),DLP(Z=-1.493,P=0.136),ED(Z=-1.493,P=0.136),and venous phase CTDIvol(Z=-0.611,P=0.541),DLP(Z=-1.151,P=0.250),and ED(Z=-1.151,P=0.250).Conclusion:The modified position utilising surgical shoulder pillows allows patients to fully stretch their necks,and improves the quality of CT images of the thyroid gland without increasing the radiation dose.关键词
甲状腺CT/图像质量/外科肩枕Key words
thyroid CT/image quality/surgical shoulder pillow分类
医药卫生引用本文复制引用
KUANG Xinru,ZHOU Yan,SU Guoyi,ZHANG Ling,LI Dapeng,WU Feiyun..采用手术肩枕改善甲状腺CT图像质量的应用研究[J].南京医科大学学报(自然科学版),2026,46(1):77-81,93,6.基金项目
国家自然科学基金(82471980) (82471980)
江苏省自然科学基金(BK20241983) (BK20241983)