中国资源综合利用2025,Vol.43Issue(12):249-252,4.DOI:10.3969/j.issn.1008-9500.2025.12.073
工业污水处理厂除磷系统工艺优化及运行效果分析
Process Optimization and Operation Effect Analysis of Phosphorus Removal System in Industrial Wastewater Treatment Plant
HOU Zhiyuan1
作者信息
- 1. Fujian Nangang Water Treatment Co.,Ltd.,Nan'an 362300,China
- 折叠
摘要
Abstract
Industrial wastewater has the characteristics of high phosphorus concentration,complex composition,and large fluctuations,which pose a serious challenge to the biological phosphorus removal system of sewage treatment plants.Several feasible phosphorus removal system process optimization strategies were analyzed,and a certain industrial wastewater treatment plant in Nan'an city was taken as the research object.In response to the unstable phosphorus removal efficiency of the Anaerobic-Anoxic-Oxic(A2O)process and the frequent exceeding of Total Phosphorus(TP)in the effluent,a process optimization application study was carried out for the Anoxic-Oxic-Anoxic-Oxic(AOAO)+chemical phosphorus removal combined process transformation and the addition of precision dosing system.This study can provide reliable experience and reference for the stable compliance and energy-saving of phosphorus removal systems in other industrial wastewater treatment plants.关键词
工业污水处理/除磷/工艺优化Key words
industrial wastewater treatment/phosphorus removal/process optimization分类
资源环境引用本文复制引用
HOU Zhiyuan..工业污水处理厂除磷系统工艺优化及运行效果分析[J].中国资源综合利用,2025,43(12):249-252,4.