Abstract
To address the issue of blade geometry optimization performance of axial-flow cooling fan under unknown boundary conditions,a parametric model of axial-flow cooling fan is established.Based on the fluid simulation software Fluent,the automatic adjustment program of momentum source term and boundary automatic adjustment program are designed by user-defined function to predict the air volume and outlet pressure of a fan with 5 blades and a blade angle of 30°(m=5,α=30°)fan.Comparing the predicted results of air volume and outlet pressure of(m=5,α=30°)fan with the measured results,it is found that the error of air volume is 3.4%and the error of outlet pressure is 2.8%.Based on the automatic adjustment program of momentum source term and the automatic adjustment program of boundary,the effect of blade number and blade Angle on the performance of the fan is studied,and the fan blade is optimized.The results show that the air volume of the optimized(m=3,α=35°)fan is increased by 33%compared with that of the(m=5,α=30°)fan,and the total pressure efficiency is increased by 23.19%,but the static pressure efficiency is reduced by 0.94%.关键词
动量源项/自动调整程序/风机叶片/风机性能/用户自定义函数Key words
Momentum source term/Automatic adjustment program/Fan blade/Fan performance/User-defined functions分类
通用工业技术引用本文复制引用
ZHANG Panhao,LU Huixia,YANG Dazhang,XIE Jing,TANG Tian,DING Guoqing..基于自适应出口的轴流冷却风机性能研究[J].制冷技术,2025,45(5):33-41,9.基金项目
上海市2022年度"科技创新行动计划"项目(No.22dz1207200),上海市2022年度"市国资委企业创新发展和能级提升项目"(No.2022023),国家重点研发计划课题(No.2022YFC3803301). (No.22dz1207200)