传感技术学报2025,Vol.38Issue(12):2130-2135,6.DOI:10.3969/j.issn.1004-1699.2025.12.003
基于CCPONS编码的单模光纤拉曼测温系统
Single Mode Fiber Raman Temperature Measurement System Based on CCPONS Coding Method
摘要
Abstract
A single mode fiber Raman temperature measurement method based on complementary correlated Prometheus orthonormal se-quence(CCPONS)is proposed to reduce the steady-state temperature measurement error of the sensor.A single pulse with a pulse width of 30 ns,a Golay code with the same pulse width of 64 bits and a CCPONS code with the same conditions are used to carry out comparative experiments.The experimental results show that the steady-state temperature measurement errors of single pulse,Golay code and CCPONS code systems are±6.5℃,±3.8℃and±2.7℃respectively under the condition of 25 km fiber length,demonstrating that CCPONS code provides an effective method for improving the performance of single-mode fiber Raman temperature measurement sensor.关键词
光纤传感/拉曼测温/互补相关标准正交序列/稳态测温误差Key words
optical fiber sensing/Raman temperature measurement/complementary correlated Prometheus orthonormal sequence/steady-state temperature measurement error分类
信息技术与安全科学引用本文复制引用
武北松,王宇,郭欣明,白清,刘昕,靳宝全..基于CCPONS编码的单模光纤拉曼测温系统[J].传感技术学报,2025,38(12):2130-2135,6.基金项目
山西省重点研发计划项目(202102130501021) (202102130501021)
中央引导地方科技发展资金项目(YDZJSX20231B004) (YDZJSX20231B004)
山西省科技创新团队项目(201805D131003) (201805D131003)
山西省专利转化专项计划项目(20250009) (20250009)