解剖学杂志2025,Vol.48Issue(6):478-480,3.DOI:10.3969/j.issn.1001-1633.2025.06.005
骶二椎弓根螺钉的应用解剖
Applied anatomy of pedicle screw in second sacral vertebrae
吴波 1龚乾龙 1杨阳 1齐飞 1冯业军 1陈仲 2黄奎1
作者信息
- 1. 长江大学附属第一医院骨科,荆州 434000
- 2. 南方医科大学珠江医院骨科中心,广州 510280
- 折叠
摘要
Abstract
Objective:To explore the feasibility of the second sacral vertebrae(S2)pedicle screw fixation and provide anatomical basis for its placement.Methods:Adult cadaveric lumbosacral specimens were selected,and parameters including screw trajectory length and lateral angulation angle were measured.Results:The lateral trajectory length was(26.87±4.28)mm,with a lateral angulation angle of(29.26±7.87)°;the medial trajectory length was(34.69±5.60)mm,with a lateral angulation angle of(44.81±4.74)°.Conclusion:S2 pedicle screw fixation is feasible with an appropriate lateral angulation angle.关键词
第2骶椎/螺钉/应用解剖Key words
second sacral vertebrae/screw/applied anatomy分类
医药卫生引用本文复制引用
吴波,龚乾龙,杨阳,齐飞,冯业军,陈仲,黄奎..骶二椎弓根螺钉的应用解剖[J].解剖学杂志,2025,48(6):478-480,3.