| 注册
首页|期刊导航|理化检验-物理分册|S31608奥氏体不锈钢换热器腐蚀泄漏原因

S31608奥氏体不锈钢换热器腐蚀泄漏原因

吕渊

理化检验-物理分册2026,Vol.62Issue(1):42-45,50,5.
理化检验-物理分册2026,Vol.62Issue(1):42-45,50,5.DOI:10.11973/lhjy-wl240294

S31608奥氏体不锈钢换热器腐蚀泄漏原因

Causes of corrosion leakage of austenitic stainless steel S31608 heat exchanger

吕渊1

作者信息

  • 1. 上海材料研究所有限公司,上海 200437
  • 折叠

摘要

Abstract

The leakage of a heat exchanger was analyzed by macroscopic observation,chemical composition analysis,scanning electron microscopy and energy spectrum analysis,X-ray diffraction analysis,metallographic examination and other methods.The results show that the chlorosilane medium in the tube side or shell side of the heat exchanger was hydrolyzed to form corrosive chloride ions,which led to stress corrosion cracking on the inner wall of the shell and in the pipeline under the combined action of corrosive medium,working stress and welding residual stress,and finally caused pipeline leakage.

关键词

换热器/S31608奥氏体不锈钢/应力腐蚀/残余应力/泄漏

Key words

heat exchanger/S31608 austenitic stainless steel/stress corrosion/residual stress/leakage