| 注册
首页|期刊导航|中国医学装备|经会阴超声动态监测胎头方向角联合头-会阴距离对剖宫产术后再妊娠阴道试产的预测价值

经会阴超声动态监测胎头方向角联合头-会阴距离对剖宫产术后再妊娠阴道试产的预测价值

龙大坚 杨茗 柏智 李仲均

中国医学装备2026,Vol.23Issue(1):64-68,5.
中国医学装备2026,Vol.23Issue(1):64-68,5.DOI:10.3969/j.issn.1672-8270.2026.01.012

经会阴超声动态监测胎头方向角联合头-会阴距离对剖宫产术后再妊娠阴道试产的预测价值

Predictive value of trans-perineal dynamic monitoring of ultrasound on direction of fetal head angle combined with head-perineum distance for TOLAC

龙大坚 1杨茗 2柏智 2李仲均3

作者信息

  • 1. 广东医科大学第一临床医学院 湛江 524023||广东医科大学附属东莞第一医院产科 东莞 523710
  • 2. 广东医科大学附属东莞第一医院产科 东莞 523710
  • 3. 广东医科大学东莞市人民医院产科 东莞 523000
  • 折叠

摘要

Abstract

Objective:To explore predictive value of trans-perineal dynamic monitoring of ultrasound on direction of fetal head angle(FHA)combined with head-perineum distance(HPD)for trial of labor after cesarean(TOLAC).Methods:A prospective study was conducted on 80 pregnant women whose single fetal were head position,who met the TOLAC signs and admitted to the First Hospital of Dongguan Affiliated to Guangdong Medical University between January 2022 and May 2024.A standardized ultrasound protocol was used to dynamically monitor FHA and HPD at 5 cm and 8 cm of cervical dilatations,and before the second stage of labor.Participants were subsequently divided into two groups based on the final delivery mode:successful vaginal birth after cesarean(VBAC)group(n=56)and repeat cesarean section(RCS)group(n=24).Receiver operating characteristic(ROC)curves were plotted,and the area under curve(AUC)of ROC curve was calculated.The efficacy was predicted by using parameters of multivariate logistic regression analysis.Results:When cervical dilatation was 5 cm,the mean FHA was(97.52±4.73)° in the VBAC group,which increased 13.21° than(84.31±4.25)° in the RCS group,showing a statistically significant difference(t=11.786,P<0.05).When cervical dilatation was 8 cm,the mean FHA was(88.93±4.85)° in the VBAC group,which increased 13.31° than(75.62±4.42)° in the RCS group,and the difference was significant(t=11.540,P<0.05).The HPD values of the VBAC group were significantly shorter than those of the RCS group when cervical dilatation was both 5 cm and 8 cm(t=3.642,4.127,P<0.05).The average change rate of HPD in VBAC group was(6.32±1.45)mm/h,which was faster 2.43 mm/h than(3.89±1.27 mm/h)in RCS group,and the difference was significant between two groups(t=3.892,P<0.05).Multivariate analysis identified"FHA≥87.8°"and"HPD≤44.5 mm"were independent predictors for VBAC(OR=4.58,3.38,P<0.05).The combination of FHA and HPD demonstrated optimal predictive performance at 8 cm of cervical dilatation,which AUC value,sensitivity and specificity were respectively 0.892,84.2%and 81.5%.The ratio of the history of prior labor stagnation of the RCS group was higher than that of the VBAS group,and there was significant difference between two groups(x2=4.732,P<0.05).There were statistically significant differences were observed between two groups regarding to age,gestational weeks,and other indicators at baseline(P>0.05).Conclusion:Dynamic monitoring of FHA and HPD can effectively predict delivery outcomes in pregnancy after cesarean section(PACS).The combination of FHA and HPD exhibits the best predictive efficacy at the cervix and nearly the entire stage.

关键词

剖宫产术后再妊娠/经会阴超声/胎头方向角(FHA)/头-会阴距离(HPD)/产程动力学

Key words

Pregnancy after cesarean section(PACS)/Perineal ultrasound/Direction of fetal head angle(FHA)/Head-perineum distance(HPD)/Labor dynamics

分类

医药卫生

引用本文复制引用

龙大坚,杨茗,柏智,李仲均..经会阴超声动态监测胎头方向角联合头-会阴距离对剖宫产术后再妊娠阴道试产的预测价值[J].中国医学装备,2026,23(1):64-68,5.

基金项目

广东省基础与应用基础研究基金(2022A1515140133) Guangdong Provincial Basic and Applied Basic Research Foundation(2022A1515140133) (2022A1515140133)

中国医学装备

1672-8270

访问量0
|
下载量0
段落导航相关论文