电力勘测设计Issue(1):38-46,9.DOI:10.13500/j.dlkcsj.issn1671-9913.2026.01.006
四回750kV线路并行走线时电磁环境研究与敏感性分析
Study and Sensitivity Analysis of Electromagnetic Environment in 750 kV Quadruple-Circuit Parallel Transmission Lines
王旭海 1周文武 2郭瑞 3王子悦 2刘超 2郝斯杰1
作者信息
- 1. 国网陕西省电力有限公司建设分公司,陕西 西安 710065
- 2. 中国电力工程顾问集团西北电力设计院有限公司,陕西 西安 710075
- 3. 武汉理工大学自动化学院,湖北 武汉 430070
- 折叠
摘要
Abstract
Using the mirror images method,empirical formula methods of CISPR and BPA,transmission line reference book 345 kV and above to analysis the influences of phase distance to ground,phase distance and parallel spacing on the ground electric field intensity,magnetic induction intensity,radio interference and audible noise under different rankings of phase conductors of 750 kV quadruple-circuit transmission lines,were found that the ground field and magnetic induction can be improved and independent of the parallel spacing under positive arrangement of phases.The RI and AN can be improved under alternating arrangement of phases.The most effective approach to improving RI and AN levels varies depending on the specific value of the phase spacing.关键词
四回750kV线路/并行间距/电磁环境/无线电干扰/可听噪声Key words
750 kV quadruple-circuit transmission lines/parallel spacing/electromagnetic environment/RI/AN分类
能源科技引用本文复制引用
王旭海,周文武,郭瑞,王子悦,刘超,郝斯杰..四回750kV线路并行走线时电磁环境研究与敏感性分析[J].电力勘测设计,2026,(1):38-46,9.