核安全2026,Vol.25Issue(1):42-50,9.
小型堆二次侧非能动余排系统运行特性研究
Operation Performance of Advanced Secondary Passive Heat Removal System in Small Reactors
李亮国 1余健明 2刘继墉 2卢冬华 2邢军 2巫英伟 3秋穗正 3苏光辉 3田文喜3
作者信息
- 1. 西安交通大学,西安 710049||中广核研究院有限公司,深圳 518026||中广核南方科技有限公司,中山 528451
- 2. 中广核研究院有限公司,深圳 518026
- 3. 西安交通大学,西安 710049
- 折叠
摘要
Abstract
Advanced Secondary Passive(ASP)heat removal system was designed to cope with Station Blackout(SBO)accident in small reactors.To investigate the operational characteristics of the ASP system in small reactors,an existing ASP Test Facility(ASPTF)was adaptively modified based on scaling criteria.The system analysis code was revised according to the flow and heat transfer characteristics of the Helical Once-Through Steam Generator(HOTSG),and a computational model for the ASPTF was established.Using this model,studies were conducted to examine the effects of various factors on ASP system performance.Calculation results indicate that the operation model of makeup water tank significantly influences flow rate peak and pressure peak during ASP operation,with simultaneous activation of the makeup water tank and Heat Exchanger(HE)proving to be the optimal operation mode.Adjustments in pipeline resistance,valve actuation time,and initial water inventory in the HE tube-side showed minimal impact on system characteristics.The water replenishment capacity of the makeup water tank critically affects the operational stability of the ASP system.关键词
小型堆/螺旋管蒸汽发生器/二次侧非能动系统/运行特性/影响因素Key words
small reactor/helical once-through steam generator/advanced secondary passive residual heat removal system/operation performance/influencing factor分类
能源科技引用本文复制引用
李亮国,余健明,刘继墉,卢冬华,邢军,巫英伟,秋穗正,苏光辉,田文喜..小型堆二次侧非能动余排系统运行特性研究[J].核安全,2026,25(1):42-50,9.