核安全2026,Vol.25Issue(1):51-59,9.
CAP1400安全级仪控系统共因失效应对和分析验证
Analysis and Validation of the Coping with Common-Cause Failure of Safety Level Instrument and Control System for CAP1400
史国宝 1王海涛 1王志超 1任文星 1吴雪雯 1刘立欣 1张国胜 1樊普1
作者信息
- 1. 上海核工程研究设计院股份有限公司,上海 200233
- 折叠
摘要
Abstract
Digital instrument and control(DI&C)technology has gradually applied in nuclear power plant(NPP),the common cause failure(CCF)due to improper design and/or use may affect the safety of NPP.Therefore,relevant guidelines at home and abroad have put forward the requirements for DI&C system defense-in-depth and diversity(D3).The consequences of all accidents of chapter 15 of the safety analysis report(SAR)concurrent with the CCF of safety level DI&C system shall be acceptable.CAP1400 is equipped with a Diverse Actuation System(DAS),which includes 6 automatic actuations and 10 manual actuations.The diversity of DAS is of sufficient quality based on qualitative and quantitative evaluations.The methodology of D3 analysis for CAP1400 is established,all accidents are calculated,the results demonstrate that the capability of CAP1400 DAS is enough to mitigate all accidents concurrent with the CCF of safety level DI&C system.关键词
数字化仪控/共因故障/纵深防御和多样性分析/CAP1400Key words
instrument control system/common cause failure(CCF),defense-in-depth and diversity(D3),CAP1400分类
能源科技引用本文复制引用
史国宝,王海涛,王志超,任文星,吴雪雯,刘立欣,张国胜,樊普..CAP1400安全级仪控系统共因失效应对和分析验证[J].核安全,2026,25(1):51-59,9.