海河水利Issue(z1):36-39,44,5.DOI:10.3969/j.issn.1004-7328.2025.增刊1.008
坎印水电站引水系统设计
Design of the Diversion System for the Kanyin Hydropower Project
杨柳荫 1陈然2
作者信息
- 1. 中水北方勘测设计研究有限责任公司,天津 300222
- 2. 北京市密云水库管理处,北京 101512
- 折叠
摘要
Abstract
The Kanyin Hydropower Project is located on the Kanyin River,a tributary of the Irrawaddy River in Myanmar.It is a small-to-medium-scale hydroelectric facility designed primarily for power generation,as well as irrigation and flood control.Utilizing the head difference between the upstream and downstream sections of the existing Kanyin Reservoir,a new auxiliary dam,intake structure,and penstock were constructed to achieve an installed capacity of 10.5 MW.Due to special geological conditions at the dam site,characterized by alternating layers of Neogene sandstone and shale prone to softening upon contact with water,the diversion system adopted a scheme combining an embedded pipe under the dam with a backfill pipe,totaling approximately 410 meters in length.Hydraulic analysis indicated a total head loss of 1.52 m for the diversion system and a water inertia time constant(Tw)of 2.72 s,eliminating the need for a surge chamber.This design satisfied hydraulic efficiency requirements while ensuring constructability and cost-effectiveness,offering a valuable reference for the design of diversion systems under similar geological conditions.关键词
引水系统/进水塔/回填管Key words
diversion system/intake tower/backfill pipe分类
建筑与水利引用本文复制引用
杨柳荫,陈然..坎印水电站引水系统设计[J].海河水利,2025,(z1):36-39,44,5.