| 注册
首页|期刊导航|建筑钢结构进展|强风下输电塔-线体系连续性失效反演研究

强风下输电塔-线体系连续性失效反演研究

张国强 李治 董优 李丹煜 贺春 刘俊才 张钰 杨汶鑫

建筑钢结构进展2026,Vol.28Issue(1):128-138,11.
建筑钢结构进展2026,Vol.28Issue(1):128-138,11.DOI:10.13969/j.jzgjgjz.20240731002

强风下输电塔-线体系连续性失效反演研究

Investigation on Progressive Failure of Transmission Tower-Line System Under Strong Winds

张国强 1李治 2董优 3李丹煜 1贺春 4刘俊才 3张钰 3杨汶鑫3

作者信息

  • 1. 中国电力科学研究院有限公司,北京 100055
  • 2. 国网天津市电力公司,天津 300010
  • 3. 香港理工大学深圳研究院,广东 深圳 518063
  • 4. 国网天津市电力公司电力科学研究院,天津 300022
  • 折叠

摘要

Abstract

Power transmission line is a typical wind-sensitive structure,which is widely distributed and very susceptible to strong winds,which results in damage or even collapse accidents,causing serious economic losses.Based on an actual collapse case of a transmission tower caused by strong wind,this paper firstly establishes a finite element model of the transmission tower-line system and simulates the wind load time histories for different wind speeds and wind attack angles with consideration of the randomness and the spatial coherence.Based on the nonlinear dynamic analysis method,the wind-induced response analyses of the transmission tower-line system under strong winds are carried out in terms of displacement and inter-segment displacement ratio(ISDR),as well as the stress responses of key steel members.The progressive failure process of the transmission tower-line system is subsequently numerically captured.The results show that,due to the tower-line coupling effect,the influence of wind speed randomness decreases gradually with the increase of the wind attack angle.The wind vibration responses of Segments 2 and 3 are relatively larger when the wind speed is 28 m·s-1 and the wind attack angle is 0°,indicating that these two segments are the weak positions of the tower.In addition,the failure mode of the tower obtained from the numerical simulation is basically the same as that of the actual tower.The buckling of some members leads to stress redistribution in the local area,and more failed members trigger the progressive collapse of the transmission towers.This study is intended to provide an available guide for the safe operation of transmission lines under strong winds.

关键词

输电塔-线体系/连续性失效/强风/薄弱区间/倒塌模式/风荷载时程曲线/振动响应分析

Key words

transmission tower-line system/progressive failure/strong wind/weak segment/collapse mode/wind load time-history curve/wind-induced response analysis

分类

信息技术与安全科学

引用本文复制引用

张国强,李治,董优,李丹煜,贺春,刘俊才,张钰,杨汶鑫..强风下输电塔-线体系连续性失效反演研究[J].建筑钢结构进展,2026,28(1):128-138,11.

基金项目

国家电网有限公司科技项目(SGTJDK00PJJS2400071) (SGTJDK00PJJS2400071)

建筑钢结构进展

1671-9379

访问量0
|
下载量0
段落导航相关论文