一种无需拆卸接地排的GIS主回路电阻快速测量方法

A Rapid Measurement Method for GIS Main Circuit Resistance Without Disassembling the Grounding Busbars

黄云程 1沈谢林 1章德华 1张国灿 1蔡舒毅 1林夏冰 1彭炜文1

作者信息

  • 1. 国网福建省电力有限公司泉州供电公司,福建 泉州 362000
  • 折叠

摘要

Abstract

To address the issues such as the need to remove and reinstall grounding busbars in tradi-tional gas-insulated switchgear(GIS)main circuit electrical equipment resistance testing,this paper pro-poses a method for rapidly measuring the single-phase contact resistance inside GIS without dismantling the grounding busbars.Using each grounding busbar as a test point,an excitation power supply are applied twice between the grounding busbars,and the corresponding electrical quantities at each test point are re-corded.Based on the circuit topology,a system of loop current equations is established.By substituting the electrical quantities obtained from the two measurements into these equations,the resistance values of each electrical equipment can be determined.Simulations results indicate that a theoretical error is 0.Consider-ing the maximum inherent error of the measuring instruments,this method enables the synchronous resist-ance measurement of all single-phase equipment in GIS,with the relative error meeting the requirements of on-site measurement.It effectively avoids the safety risks associated with dismantling grounding bus-bars,and offers advantages such as operational simplicity and reduced workload.

关键词

GIS主回路电阻/不拆卸接地排/回路电流法/快速测量

Key words

GIS main circuit resistance/non-dismantling grounding busbars/loop current method/rap-id measurement

分类

信息技术与安全科学

引用本文复制引用

黄云程,沈谢林,章德华,张国灿,蔡舒毅,林夏冰,彭炜文..一种无需拆卸接地排的GIS主回路电阻快速测量方法[J].机械与电子,2026,44(2):79-83,5.

基金项目

国网泉州供电公司揭榜挂帅项目资助(B3133024000K) (B3133024000K)

机械与电子

1001-2257

访问量1
|
下载量0
段落导航相关论文