| 注册
首页|期刊导航|南方电网技术|柔直送出下光伏送端电网交流送出线路的不对称故障距离保护方案

柔直送出下光伏送端电网交流送出线路的不对称故障距离保护方案

马红月 李岩 张涛 曹润彬 郑涛 郝治国

南方电网技术2026,Vol.20Issue(1):119-130,12.
南方电网技术2026,Vol.20Issue(1):119-130,12.DOI:10.13648/j.cnki.issn1674-0629.2026.01.012

柔直送出下光伏送端电网交流送出线路的不对称故障距离保护方案

Asymmetric Fault Distance Protection for AC Transmission Lines of PV Sending-End Grid Under VSC-HVDC

马红月 1李岩 2张涛 1曹润彬 2郑涛 1郝治国1

作者信息

  • 1. 西安交通大学电气工程学院,西安 710049
  • 2. 南方电网科学研究院,广州 510663
  • 折叠

摘要

Abstract

The fault characteristics of large-scale photovoltaic(PV)sending-end grid under VSC-HVDC are significantly affected by the control strategy and system topology form of double-end power electronic equipment,and the adaptability of traditional relay protection is challenged.Considering the fault control strategy of the converter,the topology of the sending-end grid,the transformer wiring mode and the fault location,a fault-equivalent model of the AC transmission line of the PV sending-end grid in terms of both equipment modeling and system modeling is established.By analyzing the composite sequential network of the system,the dif-ferential current characteristics of asymmetrical faults and fault distance impedance characteristics are extracted.Based on the fault characteristics of the VSC-HVDC side,asymmetric fault distance protection schemes for PV sending-end grid are proposed.For the distance protection scheme of grounded short-circuit fault,the fault distance impedance is calculated by using the sequential component characteristics,which is not affected by the transition resistance in principle.For the distance protection scheme of the ungrounded short-circuit fault,the fault distance is calculated based on the impedance complex-plane method by utilizing the fault-phase differential-current characteristics.Based on the simulation results of PSCAD/EMTDC,the proposed schemes can accurately calculate the fault distance impedance by utilizing only the single-ended quantity information of the VSC-HVDC side,reliably distinguish between internal and external faults,and improve the ability of the distance protection to tolerate the transition resistance in the double-ended weak-feeding scenario.

关键词

光伏送端电网/控制策略/故障特征/距离保护/过渡电阻

Key words

PV sending-end grid/control strategy/fault characteristics/distance protection/transition resistance

分类

信息技术与安全科学

引用本文复制引用

马红月,李岩,张涛,曹润彬,郑涛,郝治国..柔直送出下光伏送端电网交流送出线路的不对称故障距离保护方案[J].南方电网技术,2026,20(1):119-130,12.

基金项目

国家自然科学基金资助项目(U23B20112).Supported by the National Natural Science Foundation of China(U23B20112). (U23B20112)

南方电网技术

1674-0629

访问量0
|
下载量0
段落导航相关论文