| 注册
首页|期刊导航|烟草科技|常规分析用吸烟机抽吸条件测量装置和量值溯源方法

常规分析用吸烟机抽吸条件测量装置和量值溯源方法

张鹏飞 于千源 张勍 李栋 林玉红 苗芊 程东旭 慎龙舞 曾波 张颖浩 田佳丽 杨荣超 贺琛 陈志浩 史占东

烟草科技2026,Vol.59Issue(2):13-21,9.
烟草科技2026,Vol.59Issue(2):13-21,9.DOI:10.16135/j.issn1002‒0861.2025.0017

常规分析用吸烟机抽吸条件测量装置和量值溯源方法

Measuring device and data traceability for puffing conditions by smoking machines for routine analysis

张鹏飞 1于千源 1张勍 1李栋 1林玉红 1苗芊 1程东旭 2慎龙舞 1曾波 1张颖浩 2田佳丽 1杨荣超 1贺琛 1陈志浩 1史占东1

作者信息

  • 1. 中国烟草总公司郑州烟草研究院,郑州高新技术产业开发区枫杨街2号 450001
  • 2. 河南中烟工业有限责任公司,郑州市管城区第三大街9号 450016
  • 折叠

摘要

Abstract

In order to evaluate accuracy and reliability of puffing conditions of smoking machine for routine analysis(hereinafter referred to as smoking machine),a traceability method for the smoking machine measurements was established.A puffing condition measurement device consisting of a pressure drop test module,a puffing flow diagram test module,a leakage test module,a puffing time test module and a data acquisition system was developed.The device was connected to the smoking machine through the puffing channel interface,and different test modules was selected through the data acquisition system.The device was tested using standard measuring instruments,the accuracy,repeatability and stability of all the test modules were analyzed and 3 commonly used smoking machines were selected for applicability verification.The results showed that:1)The absolute value of the maximum relative error of the indication value for the pressure drop test module was 0.400%,and those of the puffing flow diagram test module,the leakage test module and the puffing time test module were 0.545%,0.857% and 0.000,respectively,all of which were less than 1.000%.2)The variable coefficients of repeated measurement results of the four test modules were all less than 0.100%.3)In the 180-day stability verification experiment,the means and standard deviations of the subgroups corresponding to the 4 test modules were all under control.4)In the applicability verification experiment of the traceability device,the test results of the 3 commonly used smoking machines all met the standard requirements.The device and traceability method could be used to calibrate the puffing conditions of different smoking machines,providing technical means for realizing the unified and standardized measurement traceability for laboratory smoking machines.

关键词

吸烟机/测量装置/测试模块/量值溯源/抽吸条件

Key words

Smoking machine/Measuring device/Test module/Measurement value traceability/Puffing condition

分类

轻工纺织

引用本文复制引用

张鹏飞,于千源,张勍,李栋,林玉红,苗芊,程东旭,慎龙舞,曾波,张颖浩,田佳丽,杨荣超,贺琛,陈志浩,史占东..常规分析用吸烟机抽吸条件测量装置和量值溯源方法[J].烟草科技,2026,59(2):13-21,9.

基金项目

国家烟草专卖局标准项目"常规分析用吸烟机通用技术条件和检定规程"(国烟科[2024]37号) (国烟科[2024]37号)

河南中烟工业有限责任公司科技项目"常规分析用吸烟机计量测试技术研究与应用"(AW2024046). (AW2024046)

烟草科技

1002-0861

访问量0
|
下载量0
段落导航相关论文