| 注册
首页|期刊导航|中国医学装备|儿童全脑全脊髓螺旋断层放疗中体位固定技术的对比研究

儿童全脑全脊髓螺旋断层放疗中体位固定技术的对比研究

骆飞 赵磊 葛永青 刘博 穆晓峰 宋丽楠

中国医学装备2026,Vol.23Issue(2):18-22,5.
中国医学装备2026,Vol.23Issue(2):18-22,5.DOI:10.3969/j.issn.1672-8270.2026.02.004

儿童全脑全脊髓螺旋断层放疗中体位固定技术的对比研究

Comparative research of different immobilization techniques for posture in craniospinal tomotherapy for children

骆飞 1赵磊 1葛永青 1刘博 1穆晓峰 1宋丽楠1

作者信息

  • 1. 首都医科大学附属北京世纪坛医院放疗科 北京 100038
  • 折叠

摘要

Abstract

Objective:To compare the positioning errors between thermoplastic mask immobilization technique and vacuum-lock bag immobilization technique for posture in craniospinal irradiation(CSI)utilizing helical tomotherapy(HT)for children,so as to provide basis for optimizing immobilization plan of posture of pediatric patients.Methods:A retrospective analysis was conducted on pediatric patients who underwent CSI at Beijing Shijitan Hospital between January and December 2024.Patients were divided into two groups based on the different immobilization device,thermoplastic mask group(n=6)and vacuum-lock bag group(n=6).The positioning errors were quantified using megavoltage CT(MVCT)verification.The positioning error of the thermoplastic mask group was compared to that of the vacuum-lock bag group at left-right(x)direction,head-foot(y)direction,abdomen-back(z)direction and cross-section rotation(Roll)direction.At the same time,the external boundary of planning target volume(PTV)of two groups were respectively calculated.Results:The positioning errors of the thermoplastic mask group and the vacuum-lock bag group on x,y,z and Roll directions were respectively[0.3 mm(-0.40,0.98),-2.85 mm(-3.68,-1.68),(2.69±1.90)mm and 0.1°(0,0.28)]and[(-0.23±2.91)mm,(-2.90±3.36)mm,(-1.12±2.74)mm and 0.1°(0,1.30)].The positioning error of the thermoplastic mask group was significantly smaller than that of the vacuum-lock bag group on x direction(U=251.0,P<0.001).Under the condition without MVCT verification in each day,the PTV external boundary values of the thermoplastic mask group and the vacuum-lock bag group w ere recommended respectively as(3 mm,5 mm and 5 mm)and(7 mm,8 mm and 7 mm)on x,y and z directions.Conclusion:Both the thermoplastic mask technique and the vacuum-lock bag technique can meet the requirements of posture immobilization in CSI utilizing HT for children,and the conditions of children should be comprehensively assessed in clinical application so as to conduct individual selection for children.

关键词

全脑全脊髓放疗(CSI)/螺旋断层放疗(HT)/体位固定技术/摆位误差

Key words

Craniospinal irradiation(CSI)/Helical tomotherapy(HT)/Technique of posture immobilization/Positioning error

分类

医药卫生

引用本文复制引用

骆飞,赵磊,葛永青,刘博,穆晓峰,宋丽楠..儿童全脑全脊髓螺旋断层放疗中体位固定技术的对比研究[J].中国医学装备,2026,23(2):18-22,5.

中国医学装备

1672-8270

访问量0
|
下载量0
段落导航相关论文