交通节能与环保2026,Vol.22Issue(1):11-16,6.DOI:10.3969/j.issn.1673-6478.2026.01.003
降雨条件下坡比与光伏组件布置位置对光伏边坡稳定性的影响
Influence of Slope Ratio and Photovoltaic Module Layout Position on the Stability of Photovoltaic Slope under Rainfall
张勇 1张小富 2刘梦楠 1李宁 1张波2
作者信息
- 1. 山东高速新能源开发有限公司,山东 济南 250014
- 2. 山东大学土建与水利学院,山东 济南 250061
- 折叠
摘要
Abstract
Under the guidance of the"dual carbon"strategic goal,setting up photovoltaic facilities on the side slopes of the main highways has become an important direction for the integration of energy and transportation.This paper conducted a non-saturated seepage analysis of photovoltaic slopes using the GeoStudio software.By setting three slope ratios and three positions for the photovoltaic components,the influence of slope ratio and photovoltaic component layout position on the stability of the photovoltaic slope under rainfall conditions was studied.The results show that rainfall has a significant impact on the stability of the photovoltaic slope,and the maximum reduction in the stability safety factor is 63.68%;there are significant differences in the influence of slope ratio and photovoltaic component layout position on the stability of the photovoltaic slope before and after rainfall;compared with the slope ratio,the influence of the photovoltaic component layout position on the stability safety factor of the photovoltaic slope is greater.关键词
降雨入渗/光伏边坡/坡比/布置位置/边坡稳定性Key words
rainfall infiltration/photovoltaic slope/slope ratio/layout position/slope stability分类
交通工程引用本文复制引用
张勇,张小富,刘梦楠,李宁,张波..降雨条件下坡比与光伏组件布置位置对光伏边坡稳定性的影响[J].交通节能与环保,2026,22(1):11-16,6.