| 注册
首页|期刊导航|电力建设|含构网型储能的系统临界短路比指标构建及影响因素

含构网型储能的系统临界短路比指标构建及影响因素

刘彬 张昊然 黄宝莹 孙黎 潘思宇 马成廉 王乐天

电力建设2026,Vol.47Issue(3):135-145,11.
电力建设2026,Vol.47Issue(3):135-145,11.DOI:10.12204/j.issn.1000-7229.2026.03.011

含构网型储能的系统临界短路比指标构建及影响因素

Construction of a Critical Short-Circuit Ratio Index for Systems with Grid-Forming Energy Storage and Influencing Factors

刘彬 1张昊然 2黄宝莹 1孙黎 2潘思宇 1马成廉 2王乐天3

作者信息

  • 1. 国网经济技术研究院有限公司,北京市 102209
  • 2. 现代电力系统仿真控制与绿色电能新技术教育部重点实验室(东北电力大学),吉林省 吉林市 132012
  • 3. 山东电力工程咨询院有限公司,济南市 250013
  • 折叠

摘要

Abstract

[Objective]Aiming at the stability issues arising from weak grid conditions(short-circuit ratio<1.5)and the large-scale centralized integration of renewable energy in desert,Gobi,and barren areas,this paper proposes a critical multiple renewable energy station short-circuit ratio calculation and discrimination method that reflects the role of grid-forming energy storage.[Methods]Based on the analysis of the multiple renewable energy station short-circuit ratio,key parameters such as virtual impedance,energy storage capacity,and connection reactance are introduced to establish a modified formula.By combining eigenvalue analysis of the extended Jacobian matrix,a real-time calculation method for the critical short-circuit ratio and stability criterion is proposed,thereby unifying the short-circuit ratio index with static voltage stability theory.Furthermore,a 3-machine 9-bus system simulation model is constructed on the electromagnetic transient simulation platform PSCAD/EMTDC.[Results]After connecting grid-forming energy storage,the system's short-circuit ratio level is significantly improved.The critical short-circuit ratio increases from 1.07 to 1.52,the wind power penetration limit rises from 50%to 54%,and the voltage sag amplitude is reduced,indicating enhanced support capability.Further simulation analysis reveals that rationally configuring the virtual impedance can improve the voltage stability margin,increasing the energy storage capacity can enhance system strength,whereas increasing the connection reactance weakens the coupling effect and reduces the critical short-circuit ratio.[Conclusions]The proposed method can accurately determine the critical stable state of the system and quantify the sensitivity of grid-forming energy storage parameters to grid strength.It addresses the deficiency of current short-circuit ratio indicators in reflecting the role of grid-forming energy storage.

关键词

构网型储能/临界短路比/电压稳定性/虚拟阻抗/弱电网

Key words

grid-forming energy storage/critical short-circuit ratio/voltage stability/virtual impedanc/weak grid

分类

信息技术与安全科学

引用本文复制引用

刘彬,张昊然,黄宝莹,孙黎,潘思宇,马成廉,王乐天..含构网型储能的系统临界短路比指标构建及影响因素[J].电力建设,2026,47(3):135-145,11.

基金项目

国家电网有限公司科技项目(5200-202456095A-1-1-ZN) (5200-202456095A-1-1-ZN)

国家自然科学基金项目(52477178) This work is supported by SGCC Technology Program(No.5200-202456095A-1-1-ZN)and National Natural Science Foundation of China(No.52477178). (52477178)

电力建设

1000-7229

访问量4
|
下载量0
段落导航相关论文