| 注册
首页|期刊导航|电力系统自动化|基于频率下降率检测的直流受端电网频率紧急控制策略

基于频率下降率检测的直流受端电网频率紧急控制策略

杨梓轩 景志滨 李洪波 陈磊 徐飞 王小海 张红光

电力系统自动化2026,Vol.50Issue(5):63-72,10.
电力系统自动化2026,Vol.50Issue(5):63-72,10.DOI:10.7500/AEPS20241213001

基于频率下降率检测的直流受端电网频率紧急控制策略

Emergency Frequency Control Strategy for DC Receiving-end Power Grid Based on Frequency Drop Rate Detection

杨梓轩 1景志滨 2李洪波 2陈磊 3徐飞 3王小海 4张红光2

作者信息

  • 1. 清华大学电机工程与应用电子技术系,北京市 100084
  • 2. 内蒙古电力(集团)有限责任公司电力调度控制分公司,内蒙古自治区呼和浩特市 010090
  • 3. 清华大学电机工程与应用电子技术系,北京市 100084||新型电力系统运行与控制全国重点实验室(清华大学),北京市 100084
  • 4. 内蒙古电力(集团)有限责任公司,内蒙古自治区呼和浩特市 010090
  • 折叠

摘要

Abstract

Emergency control plays a crucial role in the safe and stable operation of power systems.The inherent communication delays in traditional emergency control architectures are detrimental to frequency recovery,and the current emergency control measures such as load shedding and DC current modulation,have a significant impact on power users and the frequency of sending-end power grids.To address these issues,an emergency control strategy is proposed based on frequency drop rate detection.First,the shortcomings of traditional event-triggered frequency emergency control architectures are analyzed,and an emergency control architecture based on frequency drop rate detection is introduced.Next,based on traditional measures such as load shedding,DC current modulation,new control sources and control measures,such as regulable electrochemical energy storage and industrial load in the electrolytic aluminum smelting,are considered.And the regulation characteristics models for multiple control resources are established.Then,an optimization model for collaborative frequency emergency control considering multiple control resources is developed to calculate the control settings for emergency control.Finally,considering the scenarios of system operation changing states,an intraday rolling correction model for frequency emergency control strategy is established.Simulation validation of the proposed control strategy is conducted.The results shows that the emergency control strategy can reduce the timeliness requirements for distributing control settings,shorten trigger delays,and improve the dynamic frequency characteristics of systems,contributing to safe and stable operation of systems.

关键词

高压直流/受端电网/负荷/频率安全/电化学储能/紧急控制/多资源协同

Key words

high-voltage direct current/receiving-end power grid/load/frequency safety/electrochemical energy storage/emergency control/multi-resource collaboration

引用本文复制引用

杨梓轩,景志滨,李洪波,陈磊,徐飞,王小海,张红光..基于频率下降率检测的直流受端电网频率紧急控制策略[J].电力系统自动化,2026,50(5):63-72,10.

基金项目

内蒙古电力(集团)有限责任公司科技项目(内电科创[2024]5号). This work is supported by Inner Mongolia Power(Group)Co.,Ltd. (集团)