| 注册
首页|期刊导航|临床眼科杂志|原发性闭角型青光眼经白内障超声乳化联合房角分离术后房角结构参数的变化

原发性闭角型青光眼经白内障超声乳化联合房角分离术后房角结构参数的变化

徐琳琳 周熠 翟浩宇 郭建新

临床眼科杂志2026,Vol.34Issue(1):33-39,7.
临床眼科杂志2026,Vol.34Issue(1):33-39,7.DOI:10.3969/j.issn.1006-8422.2026.01.008

原发性闭角型青光眼经白内障超声乳化联合房角分离术后房角结构参数的变化

Changes in angle structural parameters of primary angle closure glaucoma after phacoemulsification com-bined with Goniosynechialysis

徐琳琳 1周熠 1翟浩宇 1郭建新1

作者信息

  • 1. 221002 江苏徐州,徐州医科大学附属医院眼科
  • 折叠

摘要

Abstract

Objective To evaluate the long-term effectiveness of this surgical procedure by studying the changes of angle structural parameters of primary angle closure glaucoma(PACG)patients who underwent phacoemulsification catatact surgery combined with goniosynechialysis.Methods This was a retrospective study.45 PACG patients 45 eyes.Collecting all Iop and AS-OCT images of these patients(included before surgery,at 1 month and 1 year after the surgery in this study).Organizing these parameters data.Measurement parameters included anterior chamber depth(ACD),anterior chamber angle 500 μm(ACA500),angle opening distance 500 μm(AOD500),angle opening distance at 750 μm(AOD750),trabecular-iris space area 500 μm(TISA500),trabecular-iris space area 750 μm(TISA750).Analyzed the changes of these parameters before and after the surgery,compare the differences in these parameters at differene time.Re-sults 45 patients underwent phacoemulsification combined with goniosynechialysis.None of them were on intraocular pressure(IOP)-lowering medication postoperatively.Postoperative IOP was significantly lower than preoperative IOP(P<0.0001).The difference in IOP at one month postoperatively compared to one year postoperatively was not statistically sig-nificant(P>0.05).Postoperative angle structural parameters:ACD,ACA500,AOD500,AOD750,TISA500,TISA750 were all increased significantly compared to the preoperative period.The difference was statistically significant(P<0.0001).Differences in individual these angle structural parameters at one month postoperatively compared with one year postoperatively were not statistically significant(P>0.05).All parameters are negatively correlated with IOP.Conclu-sions The IOP of patients with primary angle closure glaucoma had a reduction after undergoing phacoemulsification com-bined with goniosynechialysis,and these angle structural parameters,were significantly increased compared to preopera-tive.The difference between 1 month and 1 year after the surgery was not significant,indicating that the Phaco+IOL+GSL has a long-term impact,and that this operation can be used to treat PACG by restoring the functionality of the channel of aqueous humor.

关键词

原发性闭角型青光眼/白内障/超声乳化吸除术/房角分离术/房角结构参数/前节相干光层析成像术

Key words

Primary angle closure glaucoma/Cataract/Phacoemulsification/Goniosynechialysis/Angle structural parameters/Anterior segment-optical coherence tomography

引用本文复制引用

徐琳琳,周熠,翟浩宇,郭建新..原发性闭角型青光眼经白内障超声乳化联合房角分离术后房角结构参数的变化[J].临床眼科杂志,2026,34(1):33-39,7.

临床眼科杂志

1006-8422

访问量1
|
下载量0
段落导航相关论文