| 注册
首页|期刊导航|广东电力|基于线模前行波平均变化率的多端柔性直流线路单端方向保护

基于线模前行波平均变化率的多端柔性直流线路单端方向保护

甘战 徐菁 张瑞 陈慧 郭成 陈仕龙

广东电力2026,Vol.39Issue(2):55-67,13.
广东电力2026,Vol.39Issue(2):55-67,13.DOI:10.3969/j.issn.1007-290X.2026.02.005

基于线模前行波平均变化率的多端柔性直流线路单端方向保护

Single-end Direction Protection of Multi-terminal Flexible DC Lines Based on Average Rate of Change of Line Mode Forward Travelling Wave

甘战 1徐菁 2张瑞 1陈慧 1郭成 2陈仕龙2

作者信息

  • 1. 中国南方电网有限公司超高压输电公司曲靖局,云南曲靖 655000
  • 2. 昆明理工大学电力工程学院,云南 昆明 650500
  • 折叠

摘要

Abstract

In multi-terminal flexible DC transmission lines with T-connection,the boundaries of T zone are not clearly defined and the line boundaries are asymmetrical,making it extremely challenging to accurately identify faults on both sides of T zone.To address the issue of fault location identification in multi-terminal flexible DC transmission lines,this paper proposes a single-end direction protection scheme based on the average change rate of line mode forward travelling waves.First,the propagation characteristics of the line mode forward travelling wave are analyzed when faults occur on the left side of T zone,the right side of T zone,inside T zone and outside the converter station area.Analytical expressions for the line mode forward travelling wave at different fault locations are derived,revealing the trends in the waveform characteristics of the line mode forward travelling wave as it passes through the protection devices on both sides of T zone under different fault conditions.Second,the average rate of change of the line mode traveling wave measured by the protection devices on both sides of T zone is calculated,and criteria for distinguishing for faults on the left side of T zone,the right side of T zone,inside T zone,and outside the converter station area are proposed.Based on this,a single-ended direction protection scheme for multi-terminal flexible DC transmission lines based on the average rate of change of the line mode traveling wave is proposed.Finally,extensive simulations demonstrate that this scheme can accurately identify the fault location and achieve full-line fast protection for multi-terminal flexible DC transmission lines.

关键词

多端柔性直流输电/线模前行波/波形特征/平均变化率/单端方向保护

Key words

multi-terminal flexible HVDC transmission/line mode forward travelling wave/waveform characteristic/average rate of change/singe-end direction protection

分类

信息技术与安全科学

引用本文复制引用

甘战,徐菁,张瑞,陈慧,郭成,陈仕龙..基于线模前行波平均变化率的多端柔性直流线路单端方向保护[J].广东电力,2026,39(2):55-67,13.

基金项目

国家自然科学基金项目(52067009) (52067009)