| 注册
首页|期刊导航|现代检验医学杂志|血细胞分析仪WDF和WNB散点图在血小板数量检测质量管理中的应用

血细胞分析仪WDF和WNB散点图在血小板数量检测质量管理中的应用

张宁 何晓璇 孟欣

现代检验医学杂志2026,Vol.41Issue(2):187-191,5.
现代检验医学杂志2026,Vol.41Issue(2):187-191,5.DOI:10.3969/j.issn.1671-7414.2026.02.031

血细胞分析仪WDF和WNB散点图在血小板数量检测质量管理中的应用

Application of WDF and WNB Scatter Plots in Quality Management of Platelet Count Detection Using Hematology Analyzers

张宁 1何晓璇 1孟欣1

作者信息

  • 1. 西安交通大学第一附属医院检验科,西安 710061
  • 折叠

摘要

Abstract

Objective To explore and validate the value of WBC WDF Scattergram(WDF)and WBC NRBC BASO Scattergram(WNB)in monitoring blood microagglutination,large platelets and platelet aggregation.Methods A total of 1 788 EDTA-K2 blood samples were collected from the First Affiliated Hospital of Xi'an Jiaotong University between April 2023 and December 2023.When the Mindray BC-6800 Plus automatic hematology analyzers triggered the platelet agglutination alarms,exhibited ab-normal platelet histograms,or showed abnormal Ghost regions in WDF/WNB scatter plots,the MC-80 automated morphology analyzer was used to assess the relationship between different abnormal alarms and microagglutination,platelet aggregation and large platelet.Results Among 173 samples with abnormal Ghost regions in WDF scatter plots,platelet counts decreased.Com-pared to pre-recollection levels,platelet counts significantly increased after recollection(Z=-10.009,P<0.05).Among 1252 sam-ples with abnormal Ghost zone in WNB scatter plots,the MC-80 automatic morphology analyzer revealed large platelet in 1035 cases(82.67%),and platelet aggregation in 217 cases(17.33%).There was statistically significant difference in the mean platelet volume(MPV),large platelet count ratio(P-LCR),and platelet distribution width standard deviation(PDW-SD)were significant-ly lower in platelet aggregation samples than in large platelet samples(t=9.785,8.682,8.344,all P<0.05).Platelet count(PCT)and large platelet count(P-LCC)were higher in platelet aggregation samples than in large platelets samples,with no statistically significant differences(t=-0.777,-1.490,all P>0.05).Among 200 samples with large platelet,the impedance-based platelet count(PLT-I)was 100(84,127)× 109/L,while the optical platelet count(PLT-O)was 104(85,132)× 109/L.There was no statistically significant difference between PLT-I and PLT-O(Z=-0.280,P>0.05).Among 217 platelet aggregation samples with abnormal Ghost regions on WNB scatter plots,the PLT-I was 95(77,119)× 109/L and the PLT-O was 110(89,146)× 109/L.PLT-O counts were significantly higher than PLT-I counts(Z=-2.987,P<0.05).Conclusions The process of hematology analysis and report review should integrate information from blood cell counts,WDF and WNB scatter plots,and platelet histograms to establish reasonable rules and procedures for platelet reexamination.It will be necessary to incorporate morphological analysis results for comprehensive judgment to ensure the accuracy and reliability of hematology analysis results.

关键词

散点图/血细胞分析仪/血小板/复检流程

Key words

scatter plot/hematology analyzer/platelets/recheck process

分类

医药卫生

引用本文复制引用

张宁,何晓璇,孟欣..血细胞分析仪WDF和WNB散点图在血小板数量检测质量管理中的应用[J].现代检验医学杂志,2026,41(2):187-191,5.

基金项目

陕西省重点研发计划项目(2021SF-343). (2021SF-343)

现代检验医学杂志

1671-7414

访问量0
|
下载量0
段落导航相关论文