数据机房对流辐射耦合换热空调系统冷却效果影响研究

张梦帆 王玙璠 郭霖 张海云 狄彦强 程远达

太原理工大学学报2026,Vol.57Issue(2):433-442,10.
太原理工大学学报2026,Vol.57Issue(2):433-442,10.DOI:10.16355/j.tyut.1007-9432.20230724

数据机房对流辐射耦合换热空调系统冷却效果影响研究

Influences of Cooling Effect of Convection-Radiation-Coupled Heat Transfer Air-Conditioning System in Data Room

张梦帆 1王玙璠 1郭霖 2张海云 2狄彦强 3程远达1

作者信息

  • 1. 太原理工大学 土木工程学院,山西 太原
  • 2. 山西建筑工程集团有限公司,山西 太原
  • 3. 中国建筑科学研究院 中国建筑技术集团有限公司,北京
  • 折叠

摘要

Abstract

[Purposes]It is meaningful to solve the local hot spot problem generated by high-tem-perature components inside cabinet server and at the same time to reduce the energy consumption of air conditioning system in data room.[Methods]A numerical model containing the geometry of server components was established,and the local hot spot thermal image was mitigated by radiating heat ex-change between radiant deflector plate and high-temperature component.The influencing factors of the cooling effect of cabinet server with radiation deflector plate were studied comparatively,and the heat supply index,heat return index,return air temperature index,and energy utilization coefficient were used to evaluate and analyze the thermal environment of server room;on this basis,key parame-ters such as the air supply temperature,the installation angle,and the temperature of the radiation plate of the new convection-radiation-coupled heat exchanger air-conditioning system were opti-mized.[Results]The results show that the numerical model including the geometry of server compo-nents can better reflect the airflow organization and temperature distribution inside the cabinet.The thermal environment of the server room with 45° radiation deflector plate is the best at the same air supply temperature.The air supply temperature of the new convection-radiation-coupled heat ex-changer and air conditioning system can be as high as 22℃,which is 4℃higher than that of the tradi-tional convection air conditioning system,and the power consumption of the server room air condition-ing system can be saved by 12.95%.When radiation deflector temperature rises from 16 to 21℃,the system can still meet the data room air conditioning design requirements,and the air conditioning sys-tem power consumption can be further reduced by 1.05%.

关键词

数据机房/局部热点/对流辐射耦合换热/数值模拟/辐射导流板

Key words

data room/local hot spot/convection-radiation-coupled heat transfer/numerical simulation/radiation deflector plate

分类

建筑与水利

引用本文复制引用

张梦帆,王玙璠,郭霖,张海云,狄彦强,程远达..数据机房对流辐射耦合换热空调系统冷却效果影响研究[J].太原理工大学学报,2026,57(2):433-442,10.

基金项目

山西省科技厅中央引导地方科技发展资金项目(YDZJSX2021A022) (YDZJSX2021A022)

太原理工大学学报

1007-9432

访问量0
|
下载量0
段落导航相关论文