| 注册
首页|期刊导航|眼科新进展|不同锥体位置圆锥角膜的生物力学特征分析

不同锥体位置圆锥角膜的生物力学特征分析

韩懿梅 王雁 陈萱 李双成

眼科新进展2026,Vol.46Issue(3):203-209,7.
眼科新进展2026,Vol.46Issue(3):203-209,7.DOI:10.13389/j.cnki.rao.2026.0036

不同锥体位置圆锥角膜的生物力学特征分析

Biomechanical characteristics of keratoconus with different conepositions

韩懿梅 1王雁 2陈萱 3李双成3

作者信息

  • 1. 300070 天津市,天津医科大学||300020 天津市,天津市眼科医院,天津医科大学眼科临床学院,天津市眼科与视觉科学重点实验室,南开大学附属眼科医院,南开大学眼科学研究院
  • 2. 300020 天津市,天津市眼科医院,天津医科大学眼科临床学院,天津市眼科与视觉科学重点实验室,南开大学附属眼科医院,南开大学眼科学研究院||300071 天津市,南开大学医学院
  • 3. 300071 天津市,南开大学医学院
  • 折叠

摘要

Abstract

Objective To analyze the biomechanical characteristics of keratoconus(KC)with different cone posi-tions based on tangential curvature.Methods This retrospective study included 100 KC eyes[divided into a central group(51 eyes,within 3 mm of the corneal center)and a paracentral group(49 eyes,outside 3 mm of the corneal center)based on the location of the maximum tangential curvature on the anterior surface]and 51 normal eyes(control group).Morpho-logical and biomechanical parameters of the eyes were obtained using Pentacam and Corvis ST.After adjusting for intraocu-lar pressure(IOP)and central corneal thickness(CCT),as well as biomechanically corrected intraocular pressure(bIOP)and thinnest corneal thickness(TCT),intergroup parameter comparisons were conducted.The diagnostic efficacy of the pa-rameters was analyzed using receiver operating characteristic(ROC)curves.Results The IOP,bIOP,CCT,and TCT pa-rameters were compared between the paracentral group and the normal group,as well as between the central group and the normal group,and the differences were statistically significant(all P<0.05).Before adjustment,CBI,Integrated Radius,Max Inverse Radius,DA Ratio Max(1 mm),Peak Dist,dArc Length Max,cCBI,Radius,A1 Deflection Area,A1 Deflection Amp.,and HC dArc Length parameters were compared between the paracentral group and the central group,and the differ-ences were statistically significant(all P<0.05).After adjusting CCT and IOP,TCT and bIOP,there were still 11 mechanical parameters with statistically significant differences between groups(all P<0.05).The ROC curve analysis results showed that TBI,cCBI,CBI,Integrated Radius,and Max Inverse Radius had a higher ability to distinguish central KC from normal cornea(AUC=1.000,1.000,1.000,0.998,0.997),while their diagnostic efficiency decreased when distinguishing paracen-tral KC from normal cornea(AUC=1.000,0.968,0.968,0.936,0.948).Conclusion The position of the cone is a key variable affecting the biomechanical performance of KC.There is a significant biomechanical difference between central and paracentral KC,and this difference is independent of corneal thickness and IOP.When diagnosing early KC,clinicians should comprehensively judge biomechanical parameters based on the cone position to improve the accuracy of clinical screening and diagnosis.

关键词

圆锥角膜/锥体位置/角膜生物力学

Key words

keratoconus/cone position/corneal biomechanics

分类

医药卫生

引用本文复制引用

韩懿梅,王雁,陈萱,李双成..不同锥体位置圆锥角膜的生物力学特征分析[J].眼科新进展,2026,46(3):203-209,7.

基金项目

国家自然科学基金面上项目(编号:82271118) (编号:82271118)

国家重点研发计划项目(编号:2022YFC2404502) (编号:2022YFC2404502)

天津市科技计划项目(编号:21JCZDJC01190) (编号:21JCZDJC01190)

天津市卫生健康科技项目(编号:TJWJ2022XK036) (编号:TJWJ2022XK036)

天津市医学重点建设学科建设项目资(编号:TJYX-ZDXK-3-004A-3) (编号:TJYX-ZDXK-3-004A-3)

眼科新进展

1003-5141

访问量0
|
下载量0
段落导航相关论文